A. Description of modulbox / modulbox MAX
The modulbox is a modular, mobile exhibition system in a steel
frame construction.
The side walls each consist of three foldable elements: folding roof,
accessible platform and door leaves.
The modulbox is rainproof and has been developed for outdoor and
indoor use. The outer dimensions of a modulbox MAX are approx.
2.48m x 4.48m x 2.85m (w x d x h) when closed, the total weight is
between 1.4 t and 2.4 t depending on the equipment.
An electromechanical lifting system for assembly and dismantling
can be integrated as an option.
The usable inside area is approx. 8m² plus approx. 4m² or 7.5m²
open area per open platform under canopies (outside space).
As an additional feature, the roof surface can be equipped as a
terrace so that it can be walked on, but this turns the overall system
into a „flying structure".
The modulbox can be opened through the various opening states
and
Coupling combinations realize a number of installation variants.
The following graphic provides an overview of these combination
options.

Advertisement

loading
Need help?

Need help?

Do you have a question about the modulbox and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mo Systeme modulbox

  • Page 1 / modulbox MAX 2020 A. Description of modulbox / modulbox MAX The modulbox is a modular, mobile exhibition system in a steel frame construction. The side walls each consist of three foldable elements: folding roof, accessible platform and door leaves.
  • Page 2 Modulbox mo systeme does not assume any guarantee or as- surance that all necessary official approvals will be issued. A type approval is available for the modulbox. This can be pre- sented to the building authorities on site. Flying construction If a modulbox / modulbox MAX is equipped with a roof terrace, the structure becomes a flying structure.
  • Page 3 Übersicht modulbox MAX Aufstellvarianten overview MAX layouts...
  • Page 4 Position Unterlegplatten position plates Aufstellung auf Unterlegplatten / set up on pla- 6 Platten, Position mit Aufklebern am Rahmen markiert / place 6 plates below green stickers ONLY keine Platten unter die Containerlocks ! / no plates under container locks !
  • Page 5 Position Unterlegplatten position plates Aufstellung auf Unterlegplatten / set up on pla- 6 Platten, Position mit Aufklebern am Rahmen markiert / place 6 plates below green stickers ONLY keine Platten unter die Containerlocks ! / no plates under container locks !
  • Page 7 Transport with trailer and lifting system (special equipment) Lifting drive The modulbox has an electromechanical lifting system for loading and unloading on the trailer. Details on the operation follow below in this chapter Driving as a trailer combination The following points must be observed when driving with a loaded trailer: The legal regulations for vehicles with trailers in commercial traffic must be observed.
  • Page 8 Emergency control The relays of the motor control are equipped with additional switches. These are located next to the failure monitors inside the modulbox in a plastic housing. If the feed to the switching element is damaged or has failed, the modulbox can be moved by pressing the appropriate button...
  • Page 9 - Remove the drive voltage lead - Secure the module box with transport straps - Attach the trailer to the towing vehicle The modulbox MAX is connected to the transport trailer using standard container locks...
  • Page 17 Hinweis / note den Anhänger immer manuell unter der modulbox platzieren und entfernen, den Anhänger nie angekoppelt unter der modulbox bewegen. always place trailer manually under box...
  • Page 19 D. Assembly instructions Remove the transport or protective tarpaulin Open the side straps and zippers. option A Enter the roof via a ladder and pull the tarpaulin onto the roof and fold it up there. Warning notice for stepping on the roof: Use only suitable ladders Make sure the ladder is stable Without the special roof terrace construction, the main roof can only be...
  • Page 20 Interior & electrical system The floor of the interior consists of individual inlaid panels. The electrical system of the modulbox is located in the ceiling area under the surrounding perforated metal sheets.
  • Page 21 The supply takes place via a 230V / 16A safety plug which is pulled out on the back (side C) of the modulbox below the building frame. A green sticker attached to the base frame indicates the position of the plug behind it.
  • Page 22 separately and connected to the unfolded stairs via an angle lock. The banisters are opened on both sides and locked with locking screws. The terrace may only be entered via the stairs after the banisters have been unfolded and secured. The terrace railings are opened and secured in the same way as the banisters.
  • Page 23 Between wind strength BF9 and BF10 (wind speeds 76km / h -100km / h) the modulbox must be put into the folded transport state. At wind speeds above this there is a risk of losing the modulbox, appropriate protective measures are to be taken by the user.
  • Page 24 Übersicht modulbox MAX mit Terrasse overview MAX double deck version...
  • Page 25 - When using cable drums, ensure that the cable is fully unwound Failure to comply with these rules can lead to the drives failing. On the back of the modulbox - marked in green - you will find the 230V mains connection and the plug connection for the switching element in...
  • Page 26 They must therefore not be opened or damaged under any circumstances become! Minor damage, corrosion or paint residue on the piston rod will cause the spring to fail (seals will be damaged). The cylinder barrel must not be damaged or deformed! Basically all lead to changes by third parties on the product to exclude the warranty.
  • Page 27 The folding roofs cannot open completely or only partially under diffe- rent thermal conditions. This does not mean a restriction in functionality, but is due to the tech- nical requirements of the gas springs. J. Sonstiges / Kontakt 030-92 10 55710 Büro mo systeme...
  • Page 29 -10 - +40 degrees Celsius Total: P <= 3,68kVA (230Vac/16A) electric power supply ( complete system / modulbox) :230V 50Hz, fuse protection 16A F1.1 (10A): lifting engines: P<= 2kVA >power input lifting engines : 2000W (circuit 1.1 à max 10 Amp)
  • Page 30 Zusatzausstattung : Dachaufsteller extra equipment : roofcube DACHAUFSTELLER 1- bis 4-seitig modulbox mo systeme GmbH & Co. KG Telefon: 030-41714771 Kastanienallee 29-30 Fax: 030-4171-4909 Kurzanleitung 10435 Berlin info@mo-systeme.com Ergänzung zur modulbox Bedienungsanleitung DACHAUFSTELLER: ANWENDUNG 4-SEITIG Rahmen Diagonalstrebe montieren Horizontalstrebe montieren...
  • Page 31 Auf/Abbaus without tension graphics for better setup description 1. Spanngurte lösen 1. unmount straps holding top frame Ergänzung - Bedienungsanleitung modulbox system addition - manual modulbox system 1. Spanngurte lösen 1. unmount straps holding top frame 2. Ersten Rahmen aufklappen 2.
  • Page 32 3. unfold 2nd frame 4. Querträger einhängen 4. mount cross beam 4. Querträger einhängen 4. mount cross beam Ergänzung - Bedienungsanleitung modulbox system addition - manual modulbox system 4. Querträger einhängen 4. mount cross beam 5. Stoffgrafik einkedern 5. set up tension fabric 6.
  • Page 33 7. close roofcube, see details ! 8. u.U. etwas hin und her bewegen bis Bolzen einrasten 8. move frame until studs snap in Ergänzung - Bedienungsanleitung modulbox system addition - manual modulbox system Verschluss geöffnet latch open NICHT eingerastet !
  • Page 34 : roofcube 2.0 Querriegel noch nicht eingerastet ! crossbeam stud not snapped in correctly! Korrekt correct! Ergänzung - Bedienungsanleitung modulbox system addition - manual modulbox system Lichtkegel kann manuell eingestellt wer- den . adjust manually Lichtsteueung im Innenraum...
  • Page 35 Zum Tranpsort Spanngurte für den obe- ren Rahmen nicht vergessen ! For transport strap down top frame ! Ergänzung - Bedienungsanleitung modulbox system addition - manual modulbox system VOR jedem Transport prüfen u.U. etwas hin und her bewegen bis Bol-...
  • Page 36 Zusatzausstattung Fledermaussegel extra equipment : bat wing ECKÜBERDACHUNG modulbox mo systeme GmbH & Co. KG Telefon: 030-41714771 Kastanienallee 29-30 Fax: 030-4171-4909 Kurzanleitung 10435 Berlin info@mo-systeme.com Ergänzung zur modulbox Bedienungsanleitung Aufbau Planenkeder im Profil Arretierung erstes Klappdach zweites Klappdach nach unten/oben an-/auf- knüpfen...
  • Page 37 Rahmen stehen. platform must be 100% level with mo- dulbox Hineinschieben push carefully and slowly inside Ergänzung - Bedienungsanleitung modulbox system addition - manual modulbox system Befestigung am Rahmen zum Transport fix to frame for transport Halterung prüfen vor jedem Transport prüfen !
  • Page 38 Zusatzausstattung Box-in-Box extra equipment : box-in-box geöffnet open Steckbolzen einführen fix position with studs Steckbolzen einführen fix position with studs Ergänzung - Bedienungsanleitung modulbox system addition - manual modulbox system...
  • Page 39 - check regulary that foot has contact to floor plate to prevent ground sack ! Ergänzung - Bedienungsanleitung modulbox system addition - manual modulbox system Hinweis: Plattform nicht überstrecken note : no more than 90 degrees Plattformen nicht überstrecken !
  • Page 40 Drive with transport cover ONLY ! In Behausung auch ohne Plane. If driven inside > no transport cover is okay ! Immer mit Transportplane fahren ! Drive with transport cover ONLY ! Ergänzung - Bedienungsanleitung modulbox system addition - manual modulbox system...
  • Page 41 Hubsystem (Sonderausstattung)
  • Page 42 Lichtdecke Variante Leuchtstoffröhren...
  • Page 44 GmbH & Co. KG Neumagener Str 42 13088 Berlin The modulbox is a patended design registered at German Patent and Trade Mark Office. Subjects to change without notice.

This manual is also suitable for:

Modulbox max