Fisher & Paykel DE4060M Installation Instructions And User Manual page 15

Vented clothes dryer
Table of Contents

Advertisement

Before a rear venting option is installed the dryer must be changed from the front
venting factory setup. Remove the outlet grille from the front left-hand side and replace
with the outlet cover from the rear left-hand side. These covers should be gently pried
at the sides to prevent damage.
External venting options
Kits are available that allow the dryer to be vented
upwards or to the side.
The dryer can be vented directly through the wall with
a kit, in combination with the duct adaptor supplied
with the dryer.
Note: the vent system should be less than two metres
long with no more than three 90⁰ bends.
Internal venting
Front venting is the only option for internal venting.
The dryer is set up for front venting when it leaves
the factory.
Note: where possible all efforts should be made to
vent the dryer externally to avoid moisture build up
around the dryer.
Electrical connection
This appliance must be connected to a
1
220V – 240V, 50Hz, sinusoidal, 10A electrical supply.
Uncoil the power cord, remove and discard the plastic
2
pin cover and plug into a power socket.
Connect the appliance to an earthed outlet protected
3
by a fuse of suitable capacity.
Check the power cord for damage and make sure it is
not squashed or twisted when installing the dryer.
Always remove the power cord from the power socket
by the plug, not by the cord.
IMPORTANT!
Do not touch or operate the dryer with wet hands or with bare feet.
A damaged power cord must be replaced by a Fisher & Paykel trained and supported
service technician. The appliance must not be operated until it is repaired, as there is
risk of electric shock.
Do not operate this dryer if it has been damaged during transport. Contact your
Fisher & Paykel dealer or Fisher & Paykel trained and supported service technician.
INSTALLATION INSTRUCTIONS
External venting with kit part
number PD-DK4W
External venting with kit part
number PD-SVHCW4
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

De5060mDe7060m