Error Messages - IBM ThinkPad 570E Hardware Manual

Ibm thinkpad 570e: hardware guide
Hide thumbs Also See for ThinkPad 570E:
Table of Contents

Advertisement

Symptom-to-FRU index
Symptom or error
02F5
DIMM test failure
02F6
Software NMI failure
02F7
Fail—safe timer NMI failure

Error messages

Symptom or error
Device address conflict
Allocation error for: device
Failing bits: nnnn
Invalid system configuration
data
I/O Device IRQ conflict
Operating system not found
44
ThinkPad 570 and 570E Hardware Maintenance
Manual
FRU or action, in
sequence
1. DIMM.
2. System board.
1. DIMM.
2. System board.
1. DIMM.
2. System board.
FRU or action, in
sequence
1. Load Setup Defaults
in IBM BIOS Setup
Utility.
2. Backup battery.
3. System board.
1. Load Setup Defaults
in IBM BIOS Setup
Utility.
2. Backup battery.
3. System board.
1. DIMM.
2. System board.
1. DIMM.
2. System board.
1. Load Setup Defaults
in IBM BIOS Setup
Utility.
2. Backup battery.
3. System board.
1. Enter IBM BIOS
Setup Utility and see
whether the hard disk
drive and diskette
drive are properly
identified.
2. Diskette drive.
3. Hard disk drive.
4. System board.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinkpad 570Mt 2643Mt 2644

Table of Contents