ABORTED CHARGE
If charging cannot be completed normally, charging will abort. When charging
aborts, the charger's output is shut off and the Clamps Reversed/Bad Battery
(red) LED will light. Do not continue attempting to charge this battery. Check the
battery and replace, if necessary.
DESULFATION MODE
If the battery is left discharged for an extended period of time, it could become
sulfated and not accept a normal charge. If the charger detects a sulfated
battery, the charger will switch to a special mode of operation designed for such
batteries. If successful, normal charging will resume after the battery is desulfated.
Desulfation could take 8 to 10 hours. If desulfation fails, charging will abort and the
Clamps Reversed/Bad Battery

13. MAINTENANCE AND CARE

A minimal amount of care can keep your battery charger working properly for years.
• Clean the clamps each time you are finished charging. Wipe off any battery fluid that
may have come in contact with the clamps, to prevent corrosion.
• Occasionally cleaning the case of the charger with a soft cloth will keep the finish
shiny and help prevent corrosion.
• Coil the input and output cords neatly when storing the charger. This will help
prevent accidental damage to the cords and charger.
• Store the charger unplugged from the AC power outlet, in an upright position.
• Store inside, in a cool, dry place. Do not store the clamps on the handle, clipped
together, on or around metal, or clipped to the cables.