This circuit closes (LED ON) when the Light Curtain is rendered inoperative during fire service.
F/R – Front or Rear Opening – The F/R circuit is a NORMALLY OPEN (LED OFF) circuit for a
FRONT Opening and NORMALLY CLOSED (LED ON) circuit for a Rear Opening. This Input is wired
by COURION at the factory.
iLEARN EXPANSION MODULE RELAY OUTPUTS
DO – Doors In Open Position [OTB 10/11] – The DO circuit is a NORMALLY OPEN (LED OFF) relay
that closes (LED ON) when the Hoistway Doors and Car Gate are not in an OPEN position. During
Start Up or a Restart of the System, and the Door position is not known, the DO Relay will close (LED
ON) when the Car Gate is not in an OPEN position.
NO – Doors Not Operating [OTB 12/13] – The NO circuit is a NORMALLY OPEN (LED OFF) relay
that closes (LED ON) when the iLEARN Door Control is non-operational.
DC – Doors in Closed Position [DC 1/2] – The DC circuit is a NORMALLY OPEN (LED OFF) relay
that closes (LED ON) when the Hoistway Doors and Car Gate are in any OPEN position or the power
closing cycle is not complete.
RE – Reversing Edge Tripped [OTB 14/15] – The Reversing Edge Tripped circuit is a NORMALLY
CLOSED relay that Courion energizes to OPEN (LED ON). The RE Relay closes (LED OFF) when
the Gate Reversing Edge is tripped.
LC – Light Curtain Tripped [OTB 14/16] – The Light Curtain Tripped circuit is a NORMALLY CLOSED
relay that the Courion Control energizes to OPEN (LED ON). The LC Relay closes (LED OFF) when
the Light Curtain is tripped.
Doors at rest in
Closed Position
62
iLEARN
System Manual
Doors at rest in
Open Position
ver.071217-2.10