Wiring Color Code

CASE MUST BE GROUNDED
NOTE:
Refer to label affixed to case to determine the actual
configuration as checked in the "TYPE INSTALLED"
boxes.

Electrical Circuit Identification

Standard lighting for all models will be full length fluorescent
lamps located on the front of the parent case. The switch
controlling the lights is located on the parent case .

stocking

Improper temperature and lighting will cause serious
product loss. Discoloration, dehydration and spoilage
can be controlled with proper use of the equipment and
handling of product. Product temperature should always
be maintained at a constant and proper temperature.
This means that from the time the product is received,
through storage, preparation and display, the temperature
of the product must be controlled to maximize life of the
product. Hussmann cases were not designed to "heat up"
or "cool down" product - but rather to maintain an item's
proper temperature for maximum shelf life. To achieve the
protection required always:
1. Minimize processing time to avoid damaging
temperature rise to the product. Product should be
at proper temperature.
. Keep the air in and around the case area free
of foreign gasses and fumes or food will rapidly
deteriorate.
3. Maintain the display merchandisers temperature
controls as outlined in the refrigerator section of this
manual.
4. Do not place any product into these refrigerators
until all controls have been adjusted and they
are operating at the proper temperature. Allow
merchandiser to operate a minimum of 6 hours
before stocking with any product.

electrical

ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
This includes (but not limited to) Fans, Heaters

field Wiring and serial Plate amperage

Field Wiring must be sized for component amperes printed
on the serial plate. Actual ampere draw may be less than
specified. Field wiring from the refrigeration control panel to
the merchandisers is required for refrigeration thermostats.
Case amperes are listed on the wiring diagram, but always
check the serial plate.

Ballast location

Ballasts are located within the access panel that runs the
length of the rear of the case. Refer to diagram on page 6.

User information

5. When stocking, never allow the product to extend
beyond the recommended load limit. air discharge
and return air flow must be unobstructed at all
times to provide proper refrigeration.
6. There are vents located at the base of the front of the
glass, just above the front rail. These vents supply a
continuous, gentle flow of air across the front glass
which inhibits condensation. do not place any
signs or other restrictive objects on the front of
the refrigerator that will block these vents.
7. Keep the service doors closed (when applicable).
Refrigeration performance will be seriously affected
if left open for a prolonged period of time.
8. Avoid the use of supplemental flood or spot lighting.
Display light intensity has been designed for
maximum visibility and product life at the factory.
The use of higher output fluorescent lamps (H.O.
and V.H.O.), will shorten the shelf life of the product.

important steps

1. Do not set temperature too cold, as this causes
product dehydration. Product temperature:
33°-35°f!.
Set thermostat to cut in at 8°F discharge air. Meat
holding box: 3°F. Meat prep room: 55°F. Meat
bloom box: 36°F.
7
BEFORE SERVICING
ELECTRICAL COMPONENT.
Thermostats, and Lights.