  • Page 1 R3(CR3)-M/F Combination ServiCe and Self-ServiCe meat/fiSh CaSe with rear Storage P/n r3(Cr3)-m/f-0608 INSTALLATION & OPERATION GUIDE...
  • Page 2: Table Of Contents

    Refrig. Self-Service Front Case CR3-M : Refrigerated Service Top for Meat with Gravity Coil and Refrig. Self-Service Front Case CR3-F : Refrigerated Service Top for Fish with Gravity Coil and Refrig. Self-Service Front Case Shipping damage All equipment should be thoroughly examined for shipping damage before and during unloading.
  • Page 3: Cut And Plan Views

    12" X 12" WATER. & REFRIG. MECHANICAL . STUB UP CASE FRONT 8‘ 1" 8'-2" (VARIABLE LENGTHS) R3-M CR3-M R3-F CR3-F Service Cases with Self Service Front Plan View Scale = 1/4” " Optional Dry, Refrigerated or no storage " "...
  • Page 4: Installation

    Please read these instructions completely before beginning case installation. location The refrigerated merchandisers have been designed for use only in air conditioned stores where temperature and humidity are maintained at or below 75°F and 55% relative humidity. DO NOT allow air conditioning, electric fans, ovens, open doors or windows (etc.) to create air currents around...
  • Page 5 rev. 0608 5. Apply liberal beads of case joint sealant (butyl) to the areas (solid dark lines) shown in the diagram below (Fig.2, #1) of the first case. do not USe PlUmber’S PUttY! fig.2, #1 do not USe PlUmber’S PUttY! Plumber’s putty will not allow the cases to be fully drawn together which will cause gaps between the cases resulting in poor bodywork fit, finish and case sealing.
  • Page 6: Glass Installation/Balancing

    9.) 5. Shim to adjust until level using shims available from Hussmann (16 or 0 gauge stainless steel). 6. Check angle by using level placed on top of mini top hardware. Note: a 6" level will fit perfectly within access area.
  • Page 7 rev. 0608 Strategies for correcting glass bounce and opening overlap problems adjust hinges front – baCK. adjustments before calling for service if something seems wrong, check the following: 1. inspect the gap between the glass panels a.if pinched at the top: gap is more narrow at the top than at the bottom. Correct UNEVEN GAP and opening overlap problems by Vertically adjusting the hinge(s) to even the gap Adjust center hinge (Outer hinges stationary) As this diagram indicates, raising the middle hinge draws the bottom edges closer together.
  • Page 8 3. Strategies for correcting glass bounce and opening overlap problems adjust hinges front - baCK. A. Adjust center Hinge (Outer hinges stationary). As this diagram indicates, pulling the middle hinge further back, pulls the inside edges closer to the surface or edge which the glass rests upon.
  • Page 9: Joint Trim

    rev. 0608 installation (Cont'd) Joint trim DO NOT SEAL JOINT TRIM OR SPLASHGUARDS TO THE FLOOR! After cases have been leveled and joined, and refrigeration, electrical, and waste piping work completed, install the splashguards and joint trim where necessary. Fasten the splash guards along the top edge, or center, with 3/8"...
  • Page 10: Scale Stand Installation Instructions

    r3(Cr3)-m/f-0608 installation (Cont'd) Scale Stand installation instructions 1.- Set Scale Stand to desire location 2.- Drill holes and screw in place (with screws provided – Hex Tek S/S 10-16 X ½”) Note: Use hole pattern...
  • Page 11: Wrapping Boards Installation Instructions

    rev. 0608 installation (Cont'd) wrapping boards installation instructions Step : Measure 10 inches from top of the case. Step 1: Measure 6 inches from wrapping board end. note: line up 6 inch mark with 10 inch mark. Step 3: Use bracket center hole to align with cross mark. note: Use pencil/marker to mark hole pattern.
  • Page 12 Step 7: Mount wrap board on top of bracket using a ¼” spacer to have a gap between rear wall and board. installation (Cont'd) Step 6: Install upper support bracket Step 8: Screw bracket into wrap board (screws provided -#8 X 1 ¼”) Installation Complete r3(Cr3)-m/f-0608...
  • Page 13: Bumper Installation Instructions

    rev. 0608 bumper installation instructions Step 1: Make sure the aluminum channel and end caps are installed. Step 3: Starting on one end: while inserting the bumper, push it up against the end cap to prevent the bumper from shrinking after installation (when it gets cold).
  • Page 14 boston Series 2000 NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. note: rigid top: do not over cut. 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base.
  • Page 15 rev. 0608 boston 2000 eco Series 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base. Insert screws through the two holes of end cap and tighten. a.
  • Page 16 boston 1000 Series NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. note: rigid top: do not over cut. installation 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base.
  • Page 17: Plumbing

    rev. 0608 waste outlet and P-traP The waste outlet is located off the center of the case on one side allowing drip piping to be run lengthwise under the fixture. There are 3 drains in each fixture that can be easily located.
  • Page 18: Refrigeration

    Piping The refrigerant line outlets are located under the case. Locate first the electrical box, the outlets are then on the same side of the case but at the opposite end. Insulate suction lines to prevent condensation drippage. refrigeration lines Liquid 3/8"...
  • Page 19: Electrical

    Hussmann cases were not designed to “heat up” or “cool down” product - but rather to maintain an item’s proper temperature for maximum shelf life. To achieve the protection required always: 1.
  • Page 20: User Information

    Cleaning Hussmann recommends using a clean damp chamois, or a paper towel marketed as dust and abrasive free with 210 Plastic Cleaner and Polish available by calling Sumner Labs at 1-800-542-8656.
  • Page 21: Front Deck Pan Placement

    rev. 0608 WHEN CLEANING, DO NOT SPRAY GLASS! FRONT AND BACK GLASS IS NOT SEALED AND WILL LEAK!!! Front glass is “Lift Up Glass” that is NOT SEALED and back access doors ARE NOT SEALED and WILL LEAK if sprayed with any liquid! If you access the case from the front, be certain the glass is FULLY upright before beginning the cleaning process.
  • Page 22: Electrical Wiring Diagrams

    r3 - 2002 meat 24vaC Solenoids electrical wiring diagrams r3(Cr3)-m/f-0608 W0180016 W0180017 W0180018 W018000 1H10019...
  • Page 23: Wiring Diagrams

    rev. 0608 125-03-0020 F25T8-36" 125-03-0028 F32T8-48" 125-03-1131 F28T5-48" wiring diagrams LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST...
  • Page 24 wiring diagrams (Cont'd) 125-03-1167 F40T8-60" 125-03-1167 F40T8-60" 125-03-1128 F21T5-36" 125-03-1128 F21T5-36" 125-03-1128 F21T5-36" 125-03-1128 F21T5-36" WIRE LH4-120-L FULHAM 125-01-3267 BALLAST WIRE LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST r3(Cr3)-m/f-0608...
  • Page 25 rev. 0608 125-03-0020 F25T8-36" 125-03-0020 F25T8-36" 125-03-0028 F32T8-48" 125-03-0028 F32T8-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" wiring diagrams (Cont'd) LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST...
  • Page 26 wiring diagrams (Cont'd) 125-03-0020 F25T8-36" 125-03-0028 F32T8-48" 125-03-0020 F25T8-36" 125-03-0020 F25T8-36" 125-03-0028 F32T8-48" 125-03-0028 F32T8-48" WIRE 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" WIRE 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM...
  • Page 27 rev. 0608 125-03-0020 F25T8-36" 125-03-0028 F32T8-48" 125-03-0020 F25T8-36" 125-03-0020 F25T8-36" 125-03-0028 F32T8-48" 125-03-0028 F32T8-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" wiring diagrams (Cont'd) LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST WIRE LH3-120-L...
  • Page 28: Appendices

    They are based on confirmed field experience over many years. 1.1 The installer is responsible for following the installation instructions and recommendations provided by Hussmann for the installation of each individual type refrigerator. 1. Refrigeration piping should be sized according to the equipment manufacturer’s recommendations and installed in accordance with normal refrigeration practices.
  • Page 29: Appendix D. - Recommendations To User

    11. Is the store ambient over 75°F, 55% RH as set forth in ASHRAE Standard 7 and ASHRAE Standard 117? 1. Are the shelf positions, number, and size other than recommended by Hussmann? 13. Is there an improper application or control system? 14. Is the evaporator fan motor/blade inoperative? 15.
  • Page 30 Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling. for further technical information, please log on to http://www.hussmann.com/products/r3-mf.htm appendices (Cont'd) d) Care must be taken when cross merchandising products to ensure that potentially hazardous vegetable products are not placed in non refrigerated areas.
  • Page 31 __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ Additional copies of this publication may be obtained by contacting: Hussmann® Chino 13770 Ramona Avenue • Chino, California 91710 (909) 68-894 FAX (909) 590-4910 (800) 395-99 /Chino The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit.