During the defrost cycle, the cover gets warm
and some product softening may occur if prod-
uct is touching the cover.
Air Distribution & Rear Flue Spacer –
Air is drawn through the evaporator
from front to rear and is discharged down the
back wall, returning up the face of the glass door
to the return air grill.
Electrical Connections, Volts, Amperage and Ship Wt.
The HGL cases are supplied with a supply cord as charted below with a grounding
prong for operation on 208-230 power supplies. Do not remove the grounding prong under
any circumstances.
NOTE:
specified on the serial plate will void the warranty and may result
in serious damage to the unit. The cabinet should be supplied with
Model
HGL-1-BS/TS
HGL-2-BS/TS
HGL-3-BS/TS
Electrical –
Unit
H.P.
1-BS
¾
2-BS
1
3-BS
1 ½
1-TS
¾
2-TS
1
3-TS
1 ½
Connecting this unit to any electrical supply other than
its own service.
Cord Amperage
15
15
20
HZ/PH
Volts
60/1
208-230
60/1
208-230
60/1
208-230
60/1
208-230
60/1
208-230
60/1
208-230
NOTE -
Rear wire flue spacer must be in place as
this forms a discharge air flue at the back of
the cabinet.
Plug Nema Designation
6 – 15 P
6 – 15 P
6 – 20 P
Run
Amps
Fuse Size
9.0
15 amp
9.5
15 amp
12.5
20 amp
9.0
15 amp
9.5
15 amp
12.5
20 amp
Page 5
Ship
Wt.
667
936
1225
667
875
1146