Wiring Diagram - Hussmann HGL-1BS Installation And Service Instructions Manual

Bottom / top mount self-contained merchandisers
Hide thumbs Also See for HGL-1BS:
Table of Contents

Advertisement

DOOR & FRAME HEATERS
FRAME HEATERS
ALARM STAT
BLK
DEFROST HT RS
SENSING
DRAIN
BULB
TUBE
HT RS
COND
FAN
RED
2
R
PUR
COMPRESSOR
DEFROST CLOCK
T
3
4
X
C OMM
1
2
N
240 AC 120
RED
BLK
FAN SWITCHES
ORN
DOOR
HEATERS
BRN
BLU
RED
AS
H
BLK
1
3
5
7
BLK
9
BLK
11
BLK
13
DRAIN PAN HT RS
15
17
19
21
23
25
27
BLK
29
BLK
31
33
SENSOR
35
37
BLK
JUMPER
NC C NO
PUR
*** RED
*** ORN
***WHT
RED
***BRN
***B LK
BLK
LIGHT SWITCH
ORN
DEFROST
THERMOSTAT
RED
P
2
4
6
8
10
12
14
Z
16
BLK
18
20
22
EVAP FANS
24
26
28
30
32
34
36
38
S8
S7
REV EO # REV DATE REV BY
A
APPROVED BY
-
-
-
-
ANTHONY T8 ELECTRONI C LIGHTING
BLK
3
WHT
4
ORN
RED
8
2
BALLAST
ORN
RED
9
5
BRN/BLK
RED
10
6
BRN/BLK
RED
1
7
ANTHONY FRAME
OPTIONAL
CONDENSATE PAN
HEATER
FIELD WIRING
S6
RED
208-230 V
60 Hz
GRD
S5
1 PH
BLK
TOLERANCES UNLESS OTHERWIS E SPECIFIED: FRACTIONAL 1/32"
DECIMAL 0.031" ANGULAR 1° HOLE LOCATION & SPACING 1/64"
06/20/03
JLS
EO NUMBER
5224
UNIT
DRAWN BY:
JHB
DATE DRAWN:
11/2/98
SHEE T #
APPROVED BY
-
BLK
3
WHT
4
RED
2
BALLAST
RED
5
RED
6
RED
7
NOTE:
WIRES NOTED WITH *** ARE IN
WIRE HARNESS UP BACK OF CASE
*** HGL-2-BS
HGL-2-TS
GLOVE RSVILLE, NY 12078

WIRING DIAGRAM

INCHES
M100-2025 A
1 OF 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hgl-1tsHgl-2tsHgl-2bsHgl-3bsHgl-3tsHgl-bs

Table of Contents