Wiring Diagram - Hussmann Impact F6 Datasheet

Multi-deck frozen food
Hide thumbs Also See for Impact F6:
Table of Contents

Advertisement

Electric Defrost
Fan & Anti-Sweat
Heaters
All components must have mechanical ground, and the merchandiser must be grounded.
10 of 15
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
F6 & F6L - 6, 8, &12 ft

Wiring Diagram

Ambient Air Curtain - Muffin Fans
2
Main Anti-Sweat Heater
(Honeycomb Divider)
4-pass Foil Bond, 270W -12 ft,
180W - 8 ft, 120W - 6 ft
Main Fans
Reversing Non-Refrigerated Fans
3
120V
Neutral
Anti-sweat Heaters
WARNING
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Grayed components in 12 ft models only.
6W
17
12 ft case shown
4
1
in gray lines
12 ft case shown
in gray lines
5
Black
Red
Return Air Heater
16
1 pass Tubular Heater, 300W -12 ft
200W - 8 ft, 130W - 6 ft
Optional Stainless Steel Front
18
Rail Heater 200W -12 ft
150W - 8 ft, 100W - 6 ft
Brown & Purple
Fan and
12 ft case shown
in gray lines
9W
9W
Brown
8
120V
Power
F6/F6L Data Sheet Set