Wiring Color Code

CASE MUST BE GROUNDED
NOTE:
Refer to label illustrated above that is affixed to case
to determine the actual configuration as checked in the
"TYpe InsTALLeD" boxes.

Electrical Circuit Identification

Standard lighting for all models will be full length fluorescent
lamps located within the case at the top.
The switch controlling the lights is located on the light
fixture.
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heaters
Thermostats, and Lights.

stocking

Improper temperature and lighting will cause serious
product loss. Discoloration, dehydration and spoilage
can be controlled with proper use of the equipment and
handling of product. Product temperature should always
be maintained at a constant and proper temperature.
This means that from the time the product is received,
through storage, preparation and display, the temperature
of the product must be controlled to maximize life of the
product. Hussmann cases were not designed to "heat up"
or "cool down" product-but rather to maintain an item's
proper temperature for maximum shelf life. To achieve the
protection required always:

electrical

Field Wiring and serial plate Amperage

Field Wiring must be sized for component amperes printed
on the serial plate. Actual ampere draw may be less than
specified. Case amperes are listed on the wiring diagram,
but always check the serial plate.

Ballast Location

Ballasts are located within the light fixture. Refer to diagram
below.
CONDENSATE BOOSTER FAN
1.

User Information

1. Minimize processing time to avoid damaging
temperature rise to the product. Product should be
at proper temperature.
2. Keep the air in and around the case area free of
foreign gasses and fumes or flowers will rapidly
deteriorate.
3. Maintain the display merchandisers temperature
controls as outlined in the refrigerator section of this
manual.
4. Do not place any product into these refrigerators
until all controls have been adjusted and they
are operating at the proper temperature. Allow
merchandiser to operate a minimum of 6 hours
before stocking with any product.
6
IGFL-CRFD/CRFD 1/2-0508
T-12 LIGHTS
1. Access Panel on left side for Coil