Hussmann Impact C2-LGE Technical Data Sheet page 3

Hussmann c2-lge: data sheet
Hide thumbs Also See for Impact C2-LGE:
Table of Contents

Advertisement

Multi-deck, 3 Display Levels
Dimensions shown as inches and (mm).
C2-LGE
C2LGE
26
(661)
(Note*)
14
/
1
8
(359)
6
/
1
8
(155)
7
(199)
(Note:* Optional Accessory Items)
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF ® ) Standard #7 requirements.
P/N 0397201C
3
3
/
4
(95)
(Note*)
12
(305)
30
1
/
(Note*)
(765)
18
(406)
(Note*)
30
1
/
4
(766)
FAN
27
/
5
3
/
(703)
8
4
29
1
/
(743)
4
30
5
/
(778)
8
34
5
/
(881)
8
38
7
/
(986)
8
46
1
/
(1182)
2
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
19
(483)
8
48
(1219)
C
O
I
L
5
/
3
8
(136)
C2-LGE
Impact
Dairy / Delicatessen
Precut & Packaged Produce
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H.
Discharge Air (°F)
Evaporator (°F)
Unit Sizing (°F)
Btu/hr/ft*
Parallel
Conventional
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
Frequency (hr)
Defrost Water (lb/ft/day)
(± 15% based on case configuration and
product loading).
O
T
FF
IME
Temp Term (°F)
Failsafe (minutes)
E
G
Not Recommended
LECTRIC OR
AS
Standard Defrost Thermostat
Close on rise: close 48°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO**
Indoor Unit Only, Pressure Defrost
Termination**
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
Merchandiser Liquid Line (in.)
Merchandiser Suction Line (in.)
Estimated Charge (lb)***
4 ft
6 ft
8 ft
12 ft
***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
C2-LGE
27
21
19
C2-LGE
955
1050
C2-LGE
6
6
C2-LGE
48°F
30
C2-LGE
17°F / 7°F
48°F
1
1
/
2
3
/
8
7
/
8
1.3
1.8
2.3
3.3