Download Print this page
Hussmann Impact C2-LGEP Technical Data Sheet
Hussmann Impact C2-LGEP Technical Data Sheet

Hussmann Impact C2-LGEP Technical Data Sheet

Dairy / delicatessen precut & packaged produce

Advertisement

D
B
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Item Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
A. 6W Fan Assembly
0058698
Fan Motor, Evaporator
0142780
Fan Blade
embossing toward motor
B. 0137880
Optional Adjustable
Refrigeration Thermostat
Note: Changes are NOT underlined.
Revision A added the canopy anti-sweat heater (pages 1,
4, 5 & 8); added 4-ft and 6-ft data (pages 1, 2, 3 & 4); and
updated wiring diagrams.
Revision B returned the correct data to page 3.
Revision C returned the correct data to page 1.
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
®
Merchandisers
C
E
Wiring Item #
D
E
Item Part #
H
EATERS
C.
(1)
NA
0109417
0109417
0109418
(2)
L
B
AMPS AND
ALLASTS
D.
0376409
0376410
E.
C2-LGEP
Technical Data Sheet
P/N 0457228C
NSF
®
Certified
February 2006
E
A
Description
Wiring Item #
Canopy Anti-Sweat Heater
4 ft
6 ft
8 ft
12 ft
Ballast, Electronic
2 lamps
3 lamps
Fluorescent Lamp
Replace with like fixtures
P/N 0457228C
(3)
(4)
(5)

Advertisement

loading

Summary of Contents for Hussmann Impact C2-LGEP

  • Page 1 4, 5 & 8); added 4-ft and 6-ft data (pages 1, 2, 3 & 4); and updated wiring diagrams. Revision B returned the correct data to page 3. Revision C returned the correct data to page 1. HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. ® Wiring Item # Item Part #...
  • Page 2: Plan Views

    Refrigeration Outlet Back of case to center of refrigeration outlet (D) RH end of case to center of refrigeration outlet 2 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Dimensions shown as inches and (mm). (1835) (881) Skid/ External Base Elec.
  • Page 3 (359) (155) (199) (Note* Optional Accessory Items) NSF Certification These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ® ) Standard #7 requirements. P/N 0457228C HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. (483) (95) (Note*) (305) (765) (406) (Note*)
  • Page 4 115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52 4 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 4 ft 6 ft...
  • Page 5: Shelf Lighting

    Shelf Light Circuits Connector WARNING IRCLED NUMBERS ARTS Grayed components in 12 foot models only. = 120V N = Field G EUTRAL HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Fan Wiring Offtime Defrost Refrigeration Thermostat Light Blue Anti-Sweat Heater Shelf Lighting Connector...
  • Page 6: Light Circuits

    All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue B = Black W = White 6 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. WARNING IRCLED NUMBERS ARTS Grayed components in 12 foot models only.
  • Page 7 18 in. deep when positioned at a 0 º angle. P/N 0457228C Angle 0° 15° 30° 45° 0° HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. C2-LGEP Impact Dairy / Delicatessen Precut & Packaged Produce Top Eight (8) Shelf Hole Locations Maximum...
  • Page 8 CANOPY ANTI-SWEAT HEATER The canopy anti-sweat heater location is shown below. Connections are in the electrical wireway. Canopy Foil-covered Anti-sweat Heater 8 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Ballast Electrical Wireway Anti-Sweat Heater Wires with Purple Markers Screws Screws...