Hussmann Impact C2SLE Datasheet
Hussmann Impact C2SLE Datasheet

Hussmann Impact C2SLE Datasheet

Delicatessen/dairy precut & packaged produce

Advertisement

Quick Links

D
C
Item Part #
Description
F
A
,
T
AN
SSEMBLIES
AND
HERMOSTATS
A. 6W Fan Assembly
0058698
Fan Motor, Evaporator
115V, 6W, CW
0142780
Fan Blade
embossing toward motor
8 in., 25°, CW
B. 0411744
Standard Non-adjustable
disc type Defrost Thermostat
C. 0137880
Optional Adjustable
Refrigeration Thermostat
Note:
Changed items have been underlined.
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
®
Merchandisers
B
E
Wiring Item #
D
Item Part #
L
B
AMPS AND
ALLASTS
(1)
D. 0428002
D. 0428648
D. 0428649
E.
(2)
(3)
Data Sheet Set
P/N 0408922
NSF
November, 2002
E
E
A
Description
Ballast 1 lamp
Ballast 2 lamps
Ballast 3 lamps
Fluorescent Lamp
Replace with like fixtures
P/N 0408922
C2SLE
® Certified
Wiring Item #
(4)
(4)
(4)
(5)

Advertisement

Table of Contents
loading

Summary of Contents for Hussmann Impact C2SLE

  • Page 1 B. 0411744 Standard Non-adjustable disc type Defrost Thermostat C. 0137880 Optional Adjustable Refrigeration Thermostat Note: Changed items have been underlined. HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. ® Wiring Item # Item Part # AMPS AND ALLASTS D. 0428002 D. 0428648 D.
  • Page 2: Plan Views

    Refrigeration Outlet Right end of case to center of refrigeration outlet Back O/S of case to center of refrigeration outlet 2 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. (703) Waste Outlet (102) Water Seal (see note)
  • Page 3 8 (778) 8 (881) 8 (986) 2 (1182) in. from ) Standard #7 requirements. HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Impact Delicatessen/Dairy Precut & Packaged Produce REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H.
  • Page 4: Electrical Data

    2 Rows Canopy and 1 Row Rail 1 Row of Ledge Lights Optional Shelf Lighting 1 Row of Shelves 2 Rows of Shelves 4 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 4 ft 6 ft 8 ft 12 ft Amperes...
  • Page 5: Shelf Lighting

    120V N EUTRAL Fans ROWN Connector Connector WARNING Grayed components in 12 ft models only. = 120V NEUTRAL = FIELD GROUND HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Fan Wiring Offtime Defrost Defrost Refrigeration Termination Thermostat Thermostat Light Blue Dark Blue...
  • Page 6: Light Circuits

    All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue B = Black W = White 6 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. RANGE OR RANGE OR WARNING...
  • Page 7: Shelf Configuration

    NOTE: Shelves placed in the lower positions may be up to 16 in. deep when positioned at a 0º angle. P/N 0408922 Angle HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Top Eight (8) Shelf Hole Locations Maximum Shelf Size 12 in.
  • Page 8 5. Reassemble items as they were originally installed. NOTE: Rail lamp ballast is located behind the lower front panel. 8 of 8 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Remove Screws R e m o v e S c r e w s...

Table of Contents