Temperature control

The temperature control is located on the
condensing unit on the wall
merchandisers the control set at number 4
position will mantain product temparature
in a range of 36 ºF to 42 ºF (2.2 ºC to 5.5
ºC) .
The control is adjustable by runinig the
dial one number at clockwise to obtain
colder temperatures
counterclockwise to obtain warmer
temparatures.

Lighting

Interior light and lighted sign remain on
all time. An electronic ballast is locate on
the top or on condensing unit.

Defrost Water Evaporation

External drain plumbing is not required .
Behind the cooling unit housing cover ,
there is a tray for gathering and directing
defrost water from the evaporator coil to
condensing unit area , it serves
reservoir for the storage of the water until
it is evaporatored by a hot gas loop from
the compressor.
SERIES
MERCHANDISERS
MEDIUMTEMPERATURE
5.1 START UP / OPERATION
, For these
.
Turn it

Electrical Supply

Wiring of the unit is complete when it is
shipped form the factory
supplied with a three conductor electrical
cord wich extends from the rear of the
unit. Plug the unit into correct grounded
outlet. It is recommended that a separate
circuit be run for each cabinet to prevent
the posibility of another appliance blowing
a fuse, causing subsequent loss of product.
as a
PB2402474A
WARNING
Equipment MUST be
GROUNDED!
Plug in Instalation