Systeme De Refroidissement - Hoellinger NIAGARA Series Installation, Use And Maintenance Handbook

Table of Contents

Advertisement

F
9.2
INSTALLATION REFRIGERANTE
ANOMALIE
LE COMPRESSEUR
-
ABSENCE DE COURANT
NE DEMARRE PAS
-
THERMOSTAT EN POSITION OFF, OU REGLE AU MINIMUM
-
THERMOSTAT DEFECTUEUX
-
LA PROTECTION OVER-LOAD DU COMPRESSEUR EST DEFECTUEUSE
-
LE RELAIS DE DEMARRAGE EST DEFECTUEUX
-
LE CONDENSEUR DE DEMARRAGE EST DEFECTUEUX
-
LE COMPRESSEUR EST DEFECTUEUX
L'EAU EST FROIDE
-
VENTILATION INSUFFISANTE
MAIS L'APPAREIL
-
LE CONDENSATEUR EST SALE OU COUVERT
TRAVAILLE EXCES-
-
LE THERMOSTAT EST EN POSITION DE FROID MAXIMUM
SIVEMENT OU EN
-
LA TEMPERATURE AMBIANTE DEPASSE 32°C
CONTINU
LE COMPRESSEUR
-
FUITE DE GAZ AU NIVEAU DE L'INSTALLATION REFRIGERANTE
TRAVAILLE EN CON-
TINU, MAIS L'EAU
-
LE COMPRESSEUR EST DEFECTUEUX
N'EST PAS FROIDE
ANOMALIE
-
L'APPAREIL N'EST PAS BIEN NIVELE
APPAREIL TROP BRU-
YANT MAIS TRAVAIL-
-
DES TUYAUX TOUCHENT AUX PARTIES INTERNES A L'APPAREIL
LANT NORMALEMENT
PROVOQUANT DES VIBRATIONS
-
PRESSION TROP FAIBLE DE L'EAU EN ENTREE
L'EAU FROIDE SORT
-
ELECTROVANNE DEFECTUEUSE
DOUCEMENT OU PAS
DU TOUT
-
FILTRE EAU BOUCHE
-
LE REGULATEUR DE LA TEMPERATURE EST DEFECTUEUX ET PROVOQUE
LA CONGELATION COMPLETE DU BANC À GLAÇONS
ANOMALIE
-
LA PRESSION DU GAZ DANS LE REDUCTEUR DU CO2 EST REGLEE A
L'EAU
GAZEUSE
MOINS DE 3 BAR
EST PEU GAZEIFIEE
OU PAS DU TOUT
-
BOUTEILLE DE CO2 VIDE
-
LA TEMPERATURE DE L'EAU EN SORTIE EST ELEVEE
-
BULLES D'AIR DANS LE GAZEIFICATEUR
IL NE SORT QUE DU
-
LES SONDES DE NIVEAU SONT SALES
GAZ PAR LA SORTIE
-
LA POMPE TOURNE CONTINUELLEMENT
EAU GAZEUSE
-
LA POMPE TOURNE CONTINUELLEMENT IL Y A DE L'EAU EN ENTREE
-
LA POMPE EST BLOQUEE OU LE MOTEUR-POMPE NE TOURNE PAS
-
LE CONTRïLE DU NIVEAU EST DEFECTUEUX
-
LA SÉCURITÉ DE LA POMPE S'EST ENCLENCHEE (NON EAU)
E G O U T T E M E N T
-
ELECTROVANNE SALE
CONTINU AU NIVE-
AU DES SORTIES
-
LE CLAPET DE NON RETOUR EN ENTREE DU GAZEIFICATEUR EST SALE
L'EAU PLATE SORT
GAZEIFIEE
34
CAUSE POSSIBLE

SYSTEME DE REFROIDISSEMENT

CAUSE POSSIBLE
SYSTEME DE GAZEIFICATION
CAUSE POSSIBLE
INTERVENTION
-
VERIFIEZ L' ARRIVEE DE TENSION A LA PRISE
-
REGLEZ LA POSITION DU THERMOSTAT
-
REMPLACEZ LE THERMOSTAT
-
REMPLACEZ
-
REMPLACEZ
-
REMPLACEZ
-
REMPLACEZ LE COMPRESSEUR
-
ELOIGNEZ L'APPAREIL DU MUR
-
NETTOYEZ LE CONDENSATEUR ET ELIMINEZ LES OBSTACLES
-
REGLEZ-LE
-
NORMAL QUE L'APPAREIL TRAVAILLE A TEMPERATURE AMBIANTE ELEVEE
-
CONTACTER UN TECHNICIEN SPECIALISE (FRIGORISTE)
-
REMPLACEZ LE COMPRESSEUR
INTERVENTION
-
NIVELEZ L'APPAREIL A L'AIDE DES PIEDS REGLABLES
-
REGLEZ LA POSITION DES TUYAUX EN VEILLANT A CE QU'ILS NE TOUCHENT PAS A D'AUTRES
PARTIES
-
FAITES AUGMENTER LA PRESSION (RESERVOIR D'AIR)
-
REMPLACEZ
-
REMPLACEZ
-
FAITES FONDRE LA GLACE.
SUBSTITUER LE RÉGULATEUR DE TEMPÉRATURE
INTERVENTION
-
AUGMENTEZ JUSQU'A 3.5 – 4 BAR
-
REMPLACEZ
-
REGLEZ LA POSITION DU THERMOSTET AU MAXIMUM
-
PURGEZ LE GAZEIFICATEUR
-
CONTRïLER ET SUBSTITUER
-
IL N'Y A PAS D'EAU A L'ENTREE OU LE FILTRE DE L'EAU EST OBSTRUE
-
LE RACCORD D'ENTREE AU GAZEIFICATEUR EST BOUCHE. DEMONTEZ-LE ET NETTOYEZ-LE.
-
CONTROLEZ ET REMPLACEZ
-
CONTRïLER ET SUBSTITUER
-
VERIFIER S'IL Y A LA PRESSION SUR LE RÉSEAU
DECONNECTER ET RECONNECTER LA MACHINE AU RÉSEAU ELECTRIQUE POUR LA
REMETTRE EN SERVICE
-
DEMONTEZ L'ELECTROVANNE ET NETTOYEZ-LA
-
DEMONTER ET NETTOYER OU SUBSTITUER