Cooling System - Hoellinger NIAGARA Series Installation, Use And Maintenance Handbook

Table of Contents

Advertisement

GB
9.2

COOLING SYSTEM

ANOMALY
THE COMPRESSOR
-
POWER FAILURE
WILL NOT START
-
THERMOSTAT ON THE OFF POSITION, OR SET TO THE MINIMUM
-
FAULTY THERMOSTAT
-
THE OVER-LOAD PROTECTION OF THE COMPRESSOR IS FAULTY
-
THE STARTING RELAY IS FAULTY
-
THE STARTING CAPACITOR IS FAULTY
-
THE COMPRESSOR IS FAULTY
THE WATER IS COLD
-
LITTLE VENTILATION
BUT THE APPLIAN-
-
THE CONDENSER IS DIRTY OR COVERED
CE IS OPERATING
-
THE THERMOSTAT IS ON MAXIMUM COLD POSITION
EXCESSIVELY OR
-
THE ROOM TEMPERATURE IS HIGHER THAN 32°C
NON-STOP
THE COMPRESSOR
-
GAS LEAK FROM THE COOLING SYSTEM
WORKS CONTINUO-
USLY, BUT THE WA-
-
THE COMPRESSOR IS FAULTY
TER IS NOT COLD
ANOMALY
TOO MUCH NOISE
-
THE MACHINE IS NOT LEVELLED
COMING FROM THE
-
A FEW PIPES ARE TOUCHING SOME PARTS INSIDE THE APPLIANCE, THUS
APPLIANCE, BUT IT
CAUSING IT TO VIBRATE
IS WORKING NOR-
MALLY
THE COLD WATER
-
LOW PRESSURE OF THE INLET WATER
COMES OUT SLOWLY
-
FAULTY SOLENOID VALVE
OR NOT AT ALL
-
CLOGGED WATER FILTER
-
THE TEMPERATURE ADJUSTER IS FAULTY AND CAUSES COMPLETE
FREEZING OF THE ICE COMPARTMENT
ANOMALY
THE CARBONATED
-
THE PRESSURE OF THE GAS IN THE CO2 REDUCER IS SET TO LESS THAN
WATER IS NOT VERY
3 BARS
FIZZY OR NOT AT
-
CO2 CYLINDER EMPTY
ALL
-
THE TEMPERATURE OF THE OUTLET WATER IS HIGH
-
AIR BUBBLES INSIDE THE CARBONATOR
ONLY GAS COMES
-
THE LEVEL PROBES ARE DIRTY
OUT OF THE CAR-
-
THE PUMP TURNS CONTINUOUSLY
BONATED WATER
-
THE PUMP TURNS CONTINUOUSLY, INLET WATER IS PRESENT
OUTLET
-
THE PUMP IS BLOCKED OR THE PUMP-MOTOR IS NOT WORKING
-
THE LEVEL CONTROLLER IS FAULTY
-
THE PUMP SAFETY DEVICE HAS INTERVENED (NO WATER)
CONTINUOUS DRIP-
-
DIRTY SOLENOID VALVE
PING FROM THE OU-
TLETS
THE STILL WATER
-
THERE IS A SHORTAGE OF INLET WATER
COMES OUT CAR-
BONATED
32
POSSIBLE CAUSE
COOLING SYSTEM
POSSIBLE CAUSE
CARBONATING SYSTEM
POSSIBLE CAUSE
INTERVENTION
-
CHECK THAT THERE IS VOLTAGE IN THE PLUG
-
ADJUST THE THERMOSTAT POSITION
-
REPLACE THE THERMOSTAT
-
REPLACE IT
-
REPLACE IT
-
REPLACE IT
-
REPLACE THE COMPRESSOR
-
PLACE THE APPLIANCE AWAY FROM THE WALL
-
CLEAN THE CONDENSER OR FREE IT OF ITS OBSTACLES
-
ADJUST IT
-
IT IS NORMAL THAT THE APPLIANCE WORKS AT A CONTINUOUSLY HIGH ROOM TEMPERATURE
-
CONTACT A SPECIALISED TECHNICIAN (REFRIGERATIONIST)
-
REPLACE THE COMPRESSOR
INTERVENTION
-
LEVEL THE APPLIANCE USING THE ADJUSTABLE FEET
-
ADJUST THE POSITION OF THE PIPES, MAKING SURE THEY DO NOT TOUCH ANY OTHER PARTS
-
TAKE STEPS TO INCREASE THE PRESSURE (AUTOCLAVE)
-
REPLACE IT
-
REPLACE IT
-
MAKE THE ICE MELT.
REPLACE THE TEMPERATURE ADJUSTER
INTERVENTION
-
INCREASE UP TO 3.5 – 4 BARS
-
REPLACE IT
-
ADJUST THE POSITION OF THE THERMOSTAT TO MAXIMUM
-
CLEAN OUT THE CARBONATOR
-
CONTROL AND REPLACE
-
NO WATER IS ENTERING OR THE WATER FILTER IS BLOCKED
-
THE PIPE FITTING INTO THE CARBONATOR IS OBSTRUCTED. DISASSEMBLE AND CLEAN
-
CHECK IT AND REPLACE IT
-
CONTROL AND REPLACE
-
CHECK THAT THERE IS PRESSURE IN THE NETWORK
DISCONNECT AND RECONNECT THE MACHINE FROM THE ELECTRICAL NETWORK TO RESET IT
-
DISASSMEBLE THE SOLENOID VALVE AND CLEAN IT
-
DISASSEMBLE AND CLEAN OR REPLACE

Advertisement

Table of Contents
loading

Table of Contents