Running Fan Tests; Running A Self-Test On A Fan - Cisco SFS 7000P Hardware Installation Manual

Cisco systems hub/switch installation guide
Hide thumbs Also See for Cisco SFS 7000P:
Table of Contents

Advertisement

Chapter 5
Hardware Diagnostic Tests

Running Fan Tests

Running a Self-Test on a Fan

Step 1
Step 2
OL-9167-01 Rev. A0
fan(1)
passed
The following sections describes the fan module tests:
To perform a diagnostic self-test on a fan, follow these steps:
Identify the number of the fan you want to diagnose, if you do not already know
the number.
Enter the show fan command.
SFS-7000P# show diagnostic fan
======================================================================
======================================================================
module-type : fan
module-number : 2
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Fan Self Test Completed, Final report :
Passed=1, Failed=0, Total=1
Enter the diag fan id command.
SFS-7000P# config
SFS-7000P(config)# diag fan 1
SFS-7000P(config-diag-fan-1)# test self-test
SFS-7000P(config-diag-fan-1)# start
SFS-7000P(config-diag-fan-1)# exit
SFS-7000P(config)# exit
SFS-7000P# show diag fan
======================================================================
none
Diagnostic Tests For Fan
test : self-test
Diagnostic Tests For Fan
Cisco SFS 7000P Hardware Installation Guide
Running Fan Tests
5-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sfs 7000p

Table of Contents