Check the voltage and size of the fuse required from the rating plate fixed to the cabinet. The
supply socket must be earthed. Fuse ratings for different types of plugs are presented in the
following table:
16A Euro Schuko
13A BS 1363
16A CEE "Commando"
32A CEE "Commando"
2x16A Euro Schuko
2x13A BS 1363
3x16A CEE 3 Phase
No other appliances may be connected to the same fuse. The electrical connections for the
cabinet are shown in the wiring diagram in the plastic wallet attached to the side of the electrical
terminal box. Always replace the wiring diagram after use.
WARNING
All electrical connections must be carried out by approved and qualified personnel
and comply with all IEE and local regulations. Failure to do so could result in
personal or fatal injury.
NOTE
By default, the power cable of Visio is located on top of the cabinet.

4. Operation

The cooling is achieved by a fan evaporator system. The evaporator is located at the bottom of
the cabinet's tray. The cold air is blown to the shelves through the perforated back wall and
through the cooling cell in the top corner.
The cabinet is equipped with an electronic controller. In case the pressure rises to high, for
example because of dirt in the condenser, the controller stops the machine from running and
shows an error message (HA2).
On Visio, there is no separate switch for cabinet lights. The lights are controlled by a button
located on top left of the controller's display panel. Please see the picture on chapter Control
device.
For more information on the control system, please see the corresponding chapters.

4.1. Starting up

1. Connect the plug to the supply socket.
The compressor and fans start operating.
2. Wait for 90 minutes or until the desired temperature is reached.
The cabinet is now ready to be filled.
Version 05/2015
PLUG TYPE
ENGLISH
6