Toyotomi HTN-09IV User Manual page 33

All mounted air conditioner inverter type
Table of Contents

Advertisement

Available languages

Available languages

Requirements for electric connection
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in fixed wiring.
6. Including an circuit break with suitable capacity, please note the following table.
Air switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
Air-conditioner Circuit break capacity
09K
12K
17-18K
21-24k
33
10A
10A
10A
16A
GB

Advertisement

Table of Contents
loading

Table of Contents