Denon Home 350 Service Manual page 58

Hide thumbs Also See for Home 350:
Table of Contents

Advertisement

PROCEDURE AFTER REPLACING THE U-COM, ETC.
The procedure after replacing the u-COM (microprocessor), flash ROM, etc. is as follows.
PCB Name Ref. No.
Description
MAIN
C3
Network Module
TOUCH
IC8001 CY8C4045AZI-S413
MAIN
IC1311 W25X40CLSNIG
MAIN
IC5002 MX25L3233F
Procedure after Replacement
A : The software has been written. The software is not written at the time of replacement.
B : The software has been written. The software may need to be rewritten by version updates. Check the
version.
See
"FIRMWARE UPDATE
PROCEDURE" for information on writing the software.
C : The software has not been written. The software needs to be written after replacement.
See
"3. Updating via
USB",
"4. Service region settings update
settings update
procedures" for information on writing the software.
D : The software has been written. Be sure to rewrite with the latest software for your service region.
See
"3. Updating via
USB",
"4. Service region settings update
settings update
procedures" for information on rewrite the software.
Procedure
Remark
after Re-
placement
D
SOFTWARE : Network Module
C
SOFTWARE : MCU
C
SOFTWARE : Audio DSP
C
SOFTWARE : VUI DSP
procedures" and
"5. Service Release Type
procedures" and
"5. Service Release Type
58

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents