Denon Home 350 Service Manual page 51

Hide thumbs Also See for Home 350:
Table of Contents

Advertisement

1. Factory Initialization Mode
1.1. Actions
Various user settings are cleared. and the software is restored to the factory version.
1.2. Operations
(1) Remove the AC plug.
(2) Insert the AC plug while pressing "Bluetooth" button, and wait for more than 5 seconds.
(3) Check that the Status LEDs is now blinking in orange and then release the button.
(4) The Status LED blinks in orange while this unit is initializing.
(5) This unit automatically restarts when initialization is complete.
1.3. Initialization item
No
Items
Default
1
My Devices name
Cleared
2
Network information
Cleared
3
EQ and various user settings
Cleared
4
Firmware
Factory setting
2. User Initialization Mode
2.1. Actions
Various user settings are cleared.
2.2. Operations
(1) While the power is on, hold down the "Bluetooth" and "Connect" buttons for at least 5 seconds.
(2) Check that the Status LEDs is now blinking in orange and then release the button.
(3) The Status LED blinks in orange while this unit is initializing.
(4) This unit automatically restarts when initialization is complete.
2.3. Initialization item
No
Items
Default
1
My Devices name
Cleared
2
Network information
Cleared
3
EQ and various user settings
Cleared
51