Codabar - Mindeo CS7290-BT User Manual

Cordless image scanner
Table of Contents

Advertisement

3-23 Codabar

Read:
Format
Start character
Check digit verification: The check digit is made as the sum module 16 of the numerical values of all data
digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code ID setting: Refer to Code ID setting of
Insertion group selection: Refer to Insertion group selection of
Start/End type: Codabar has four pairs of Start/End pattern; you may select one pair to match your
application.
Start/End transmission: Refer to Start/End transmission of
Start/End character equality: By setting Enable, the start and end character of a Codabar barcode must
be the same.
Option bar code
Read
Check digit verification
Check digit transmission
Max. code length
Min. code length
Code ID setting
Data digits (variable)
3-14
Multiple-scan setting
Option
Disable
Enable
Disable
Enable
Disable
Enable
00-99
00-99
00-FF
16
(ASCII)
Check digit (optional)
3-19 Code
39.
UPC-A.
3-14
UPC-A.
3-19 Code
39.
Alpha. entry
00
01*
00*
01
00*
01
00-99
00*
00-99
00*
00-FF
16
<N>*
59
End character
Single-scan setting
*
*
*
*
*
*

Advertisement

Table of Contents
loading

Table of Contents