Specifications - Hyundai H-AR9-07H Instruction Manual

Electric air conditioner split system
Table of Contents

Advertisement

4.

3.SPECIFICATIONS

Tab.1
Indoor unit
Outdoor unit
Capacity (cooling) BTU (W)
Capacity (heating) BTU (W)
Rated power consumption (cooling) (W)
Rated power consumption (heating) (W)
Power supply V/Hz
Rated power current (cooling/heating) A
Air circulation (indoor unit) m
Air circulation (outdoor unit) m
Noise level (indoor unit) dB(A)
Noise level (outdoor unit) dB(A)
Refrigerant
Energy efficiency (cooling/heating)
EN
Electrical protection class
Degree of protection against moisture
(indoor unit)
Degree of protection against moisture
(outdoor unit)
Refrigerant piping, Liquid side / Gas side, (inch)
Max. refrigerant pipe length, m
Maximum difference in level, m
Filling of Freon, g
Operating temperature range: cooling, ° C
Operating temperature range: heating, ° C
Net weight, indoor unit (kg)
Net weight, outdoor unit (kg)
Gross weight, indoor unit (kg)
Gross weight, outdoor unit (kg)
Net dimensions, indoor unit (mm)
Net dimensions, outdoor unit (mm)
Packing dimensions, indoor unit (mm)
Packing dimensions, outdoor unit (mm)
H-AR9-07H/I
H-AR9-07H/О
/h
3
/h
3
Electric air conditioner (split system)
H-AR9-09H/I
H-AR9-09H/О
7336 (2150)
7677 (2250)
670
621
220~/50
2.91/2.70
420
1250
33/29/27/24
48
R410A
A/A
I
IPX0
IPX4
1/4;3/8
7
5
400
+18°~+43°
-7°~ +30°
6.8
21.28
8.5
23.3
690x283x199
663x254x421
740×343×264
760x343x478
9212 (2700)
9383 (2750)
840
756
220~/50
3.214/3.29
450
1250
33/30/27/24
50
R410A
A/A
I
IPX0
IPX4
1/4;3/8
7
5
540
+18°~+43°
-7°~ +30°
7.3
22.1
8.5
23.9
690x283x199
663x254x421
740x343x264
760x343x478