Overview Of Control Panel; Control Via Dmx 512 - Hansol Hurricane-AW Manual

Table of Contents

Advertisement

2. 7 Overview of Control Panel

3. Control via DMX 512

3.1. DMX Key Value
The device is controlled by DMX 512.
solenoid valve for flame(CH2) and Pump(CH4) work at the range of dmx key 200 ~ 255.
At the range of 0 to 199, the ignition, the solenoid valve and pump do not work.
3. 2. Setting Starting Address
① DMX(Yellow Color) : indicate that all the dmx connection is normal
② 001(Blue color) : indicate the Machine's DMX starting address
③ DMX Channel Set Button
M : push 3 seconds for setting "Machine DMX Add."
▶ : change the current mode to the other mode
▲ : change the channel address
The device has 19 DMX channels. The spark ignition(CH3),
Hurricane-AW
a. DMX Screen : DMX Starting address is
displayed.
b. DMX address setting button
c. Power In
d. Power Out
e. Power Switch
f.
Fuse(10ampare fuse)
g. 3 pin DMX Out
h. 3 pin DMX In
i.
Emergency Switch
5