Hansol Hurricane-AW Manual page 12

Table of Contents

Advertisement

5. Set up
1. Check the drain bolt is tightly screwed at the bottom of fuel reservoir and then charge fuel to fuel
reservoir, checking fuel level gauge at the side of fuel reservoir.
2. Check the pressure discharge manual valve is closed. Before pump starting, this manual value should
be closed. If not, the device cannot get working pressure.
3. Connect power cable and dmx signal cable and turn on the power.
4. Turn on pump channel to check.
5. Turn on electric spark channel. It is recommended that spark is activated 1 sec before a chain of flame
shooting and deactivated 1 sec after a chain of flame shooting.
6. The device is ready to start the show. For manual flame shooting, turn on flame shooting channel(CH2)
and for changing shooting angle, use Channel 1 simultaneously. For auto show, use CH5 or Bank
channels.
7. After the show, deactivate all the dmx channels to 0 and turn off the power. Then, open the pressure
discharge manual valve for remove the pressure inside the pump and pipings.
Caution
-
Check if there is any fuel leakage from fuel reservoir. At the bottom of the device, there is a fuel drain
bolt. Check if any fuel leaks from this drain bolt. This drain bolt is for cleaning fuel reservoir
periodically.
-
After fuel charging, the cap of fuel reservoir should be tightly closed. If not, the fuel can be leaked
around cap when pressure purge is made.
-
In case of wireless mode, always check wireless DMX group in order to avoid any overlap from other
wireless dmx machines or controllers.
6. Safety
Hurricane AW has some safety functions
-
The device has double solenoid valves.
-
Without pump working, electrical spark ignition is not made.
-
Without electric spark ignition, solenoid valve does not work, then flame cannot be shot.
-
The fuel level sensor is installed. Pump does not work in case that the fuel is below the determined low
level.
-
Below 6 bar, the solenoid valve for flame does not work. The solenoid valve activates only between 6
and 18 bar.
-
When the pressure reached to 18bar stops working and enter to the standby mode. When the pressure
falls below 14 bar, it works again.
Hurricane-AW