2. 6 Overview of Hurricane-AW
1. Fuel Reservoir cap
2. Pressure Discharge manual valve
3. Handle
4. Ignition & flame jet Box
5. E-stop SW
6.
Fuel Level
7. Control Panel
Pressure Discharge manual Valve is for
-
Stop or allow the pressurized liquid to flow
into the fuel reservoir from accumulator.
Before the pump working, close this VALVE
to get the working pressure. After the show,
open this VALVE to remove the pressurized
fuel from accumulator, pumps and piping.
-
When you get new machine from us, or you
use it again after fully draining, you need to
work only pump for 10 sec to remove air
inside piping, pumps and accumulator at the
open position of this VALVE.
E-Stop SW
- E-stop SW is for cutting power to solenoid
valves and spark igniters.