Specifications - Linear Acoustic AERO.100 User Manual

Audio loudness manager
Table of Contents

Advertisement

AERO.100 User Guide

8 8 8 8 Specifications

Specifications
Specifications
Specifications
Processing
Structure
Algorithms
Options
Digital I/O
AES Digital Audio I/O
Remote
Ethernet
GPI/O Control Port
Metadata Input
©2016 TLS Corp. ALL RIGHTS RESERVED
Table 11-1 Electrical
AMX 5.1 Instance: 5.1+2+2 with up to 2 downmix
outputs, dual-path upmixing and SAP/DVS capability.
AMX2.0 Instance: 2+2+2 with Auto SAP/DVS with 3 downmix outputs and SAP/DVS
capability.
AMX5x2 Intance: 2+2+2+2+2 with 2 downmix outputs and SAP/DVS capability.
AEROMAX®: ATSC A/85 and EBU R128-compliant loudness control via adjustable
wideband and multiband processing.
UPMAX®II: 5.1-channel upmixing, automatic bypass of discrete content
Dolby Digital and Dolby Digital Plus encoding; 3/2L or 2/0 for AMX5.1 instance.
AMX2.0 instance is limited to 2/0 encoding.
Dolby E Encoding
Dolby Digital, Dolby Digital Plus, and Dolby E decoding; auto sensing of coded or
PCM audio.
Nielsen Watermark Encoder
Low latency mode
Crowd Control
ITU or EBU labeled metering
All inputs are unbalanced, 75 ohm, with internal
termination 1-2, 3-4, 5-6, 7-8, AES Ref use BNC (F)
connectors.
Signal levels per SMPTE 276M/ AES-3ID-2001
All I/O can be assigned as needed
TCP/IP remote control and audio monitoring via Remote Interface software, a
Windows®-compatible application (included)
HTTP server allows get/set control from any OS
100 to 1000 BASE-T via RJ-45 connector
F-DB25 connector, 0–5 V TTL levels, pull to ground activation. 8 GPIs.
DB9-F connector, 115 kbps, pinout per SMPTE 207M (RS-422/485)
Interfaces directly with Dolby Metadata (SMPTE RDD6)