AERO.100 User Guide
Encoding options: Dolby Digital, Dolby Digital Plus and/or Dolby E.
•
GPI and Ethernet control.
•
NfRemote IP-based, full-function remote control for configuration and monitoring.
•
Nielsen® Watermark encoding option for all program outputs.
•
Internal logging of loudness measurement data, True Peak, and channel configuration
•
(acmod) and the value of dialog normalization (dialnorm) found in the Dolby encoded
bitstream for each program output.
3.3
3.3
3.3
3.3 Back Panel
Back Panel
Back Panel
Back Panel
Figure 3-1 shows the AERO.100 back panel. Its connector functions are described below from
left to right:
Analog I/O (DB9F) – not used
•
Metadata I/O (DB9F) – RS-485 metadata (no crossover cable required)
•
Reserved (RJ45) – Reserved for future use
•
ETHERNET (RJ45) – Auto-sense 100/1000 BASE-T, requires connection to stable network
•
SDI I/O (dual BNC) – Auto-sensing SD/HD, supports 16 audio channels, VANC metadata,
•
and has internal compensating video delay
Main AES I/O (BNC) – 4 AES digital audio pairs I/O
•
AES Ref (BNC) – Apply 48 kHz DARS (Digital Audio Ref Signal), or any AES signal, but not
•
video. Use only if SDI embedding is disabled.
ENC Out (BNC) – Encoder output, fed in parallel with AES digital SDI audio output pair
•
15/16
Vref (BNC) – Video reference input (supported with firmware versions
•
above.)
LTC In (BNC) – LTC timecode input (not currently supported)
•
©2016 TLS Corp. ALL RIGHTS RESERVED
Figure 3-1 AERO.100 back panel
Oct 2016
0x20000053 and
Page 17