Temperature sensor T3 (pipe temperature
sensor) switched off or short-circuited
Temperature sensor T4 (outside temperature)
switched off or short-circuited
Temperature sensor TP (compressor discharge
temperature protection) switched off or short-
circuited
Temperature sensor T1 (room temperature
sensor) switched off or short-circuited
Temperature sensor T2 (pipe temperature
sensor) switched off or short-circuited
Refrigerant leakage detector (with some units)
Malfunction of the water level alarm
Outdoor unit fan outside the normal range
(with some units)
Outdoor unit is faulty (for old communication
protocol)
Outdoor unit EEPROM fault (with some units)
IPM malfunction
Overvoltage or low-voltage protection
Maximum temperature protection of compressor
or high temperature protection of IPM module
High or low-pressure protection
(with some units)
Compressor control system failure of inverter
Table 15 Fault codes of type 4CC indoor unit
Outdoor Unit
Fault code
Content
EC 51
Outdoor unit EEPROM fault
EL 01
Communication fault between outdoor and indoor unit
PC 40
Communication fault between PCI and printed circuit board of outdoor unit
PC 08
Overcurrent protection of outdoor unit
PC 10
Low-voltage protection of outdoor unit AC voltage
PC 11
Overvoltage protector of DC-bus for outdoor unit PCB
PC 12
Overvoltage protector of DC-bus for outdoor unit PCB/341/MCE fault
PC 00
IPM module protection
PC 0F
PFC module protection
EC 71
Overvoltage defect in fan motor (DC current) of outdoor unit
EC 72
Missing phase detection of outdoor unit fan motor (direct current)
EC 07
Fan speed of outdoor unit out of control
PC 43
Phase detection protection of outdoor unit compressor
PC 44
Zero speed protection of outdoor unit
PC 45
IR control failure (outdoor unit)
PC 46
Compressor speed out of control
PC 49
Overvoltage defect in compressor
PC 30
High-pressure protection
PC 31
Low-pressure protection
PC 0A
Condenser high-temperature protection
PC 06
Compressor discharge temperature protection
PC 02
Maximum temperature protection of compressor
EC 52
Temperature sensor T3 (pipe temperature sensor) switched off or short-circuited
EC 53
Temperature sensor T4 (outside temperature) switched off or short-circuited
EC 54
Temperature sensor TP (compressor discharge temperature protection) switched off or short-circuited
Table 16 Outdoor unit fault codes
Climate 5000 L • Climate 5000iL – 6721841494 (2022/05)
Timer lamp
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
FLASH (at 2Hz)
FLASH (at 2Hz)
FLASH (at 2Hz)
FLASH (at 2Hz)
FLASH (at 2Hz)
Operation lamp (flashes)
5
5
5
6
6
7
9
12
14
5
7
2
3
7
5
Troubleshooting