OPERATION
DO NOT allow flames or sparks near fuel.
Fuel tanks/cans may be under pressure. Always loosen
fuel caps slowly allowing pressure to equalize.
NEVER refuel a unit when the engine is HOT or RUNNING!
DO NOT fill fuel tanks indoors. ALWAYS fill fuel tanks
outdoors over bare ground.
DO NOT overfill fuel tank. Wipe up spills immediately.
Securely tighten fuel tank cap and close fuel container
after refueling.
Inspect for fuel leakage. If fuel leakage is found, do not
start or operate unit until leakage is repaired.
Move at least 3 m (10 ft.) from refueling location before
starting the engine.
Mixing Instructions
1.
Fill an approved fuel container
with half of the required
amount of gasoline.
2.
Add the proper amount of
2-stroke oil to gasoline.
3.
Close container and shake to
mix oil with gasoline.
4.
Add remaining gasoline, close
fuel container, and remix.
Spilled fuel is a leading cause of hydrocarbon emissions. Some
states may require the use of automatic fuel shut-off containers to
reduce fuel spillage.
• Empty the fuel tank prior to storing the unit. Return
unused fuel to an approved fuel storage container.
Storage - Fuel storage laws vary by locality. Contact your
local government for the laws affecting your area. As a
precaution, store fuel in an approved, airtight container.
Store in a well-ventilated, unoccupied building, away from
sparks and flames.
Stored fuel ages. Do not mix more fuel than you expect to use in thirty
(30) days, ninety (90) days when a fuel stabilizer is added.
20
Fuel to Oil Mix – 50:1 Ratio
US
Gas
Oil
gal.
fl.oz.
1
2.6
2
5.2
5
13
© 10/2017 ECHO Inc.
GT-225I
Metric
Gas
Oil
L
cc
5
100
10
200
25
500