Figure 1: RUGGEDCOM WIN5137-V
1. ETH Port    2. PWR Port    3. ANT 1 Port    4. ANT 2 Port    5. RSSI LEDs    6. W.LINK LED    7. PWR LED    8. Chassis Ground
12VDC Port
ANT 1 and ANT 2 Ports
RSSI LEDs
W.LINK LED
PWR LED
Description
5
RSSI
6
W.LINK PWR
A 4-pin, female, D-Coded M12 port for power. For more information about connecting data
and power, refer to
Ports for connecting primary and secondary external antennas. For information about
connecting the antennas, refer to
Indicates the received signal strength.
LED
Indicates when the subscriber unit is connected with a base station.
State
Green (Solid)
Green (Blinking)
Indicates when power is supplied to the subscriber unit.
State
Green
Off
1
3
7
Section 2.7, "Connecting Power and
Section 2.5, "Installing the
2
4
8
Data".
Antennas".
RSSI Level
< -90
-85 to -90
-80 to -85
-75 to -80
-70 to -75
-65 to -70
-20 to -60
> -20
Description
Subscriber unit is connected to the base
station and receiving services.
Link between the subscriber unit and the
base station is down.
Description
Power is on.
Power is off.