Parts Arrangement

UNIT CONTROL
BOX
FILTER/DRIER
MUFFLER
REVERSING
VALVE
HIGH PRESSURE
SWITCH

Setting the Unit

CAUTION
In order to avoid injury, take proper precaution when
lifting heavy objects.
CAUTION
Sharp sheet metal edges can cause injury. When
installing the unit, avoid accidental contact with
sharp edges.
Outdoor units operate under a wide range of weather con-
ditions; therefore, several factors must be considered
when positioning the outdoor unit. The unit must be posi-
tioned to give adequate clearances for sufficient airflow
and servicing. A minimum clearance of 24 inches (610 mm)
between multiple units must be maintained. Refer to figure
2 for installation clearances.
HP21 Parts Arrangement
Figure 1
NOTE − A service access
clearance of 30" (762 mm)
must be maintained in front
of the service access panel.
Clearance to one side must
be 36" (914 mm). Clearance
to one of the remaining two
sides may be 12" (304 mm)
and the final side may be 6"
(152 mm).
NOTE − A clearance of 24" (610 mm)
must be maintained between two units.
NOTE − 48" (1219 mm) clearance required on top
of unit. Maximum soffit overhang is 36" (914 mm).
Page 3
OUTDOOR
FAN
TRANSFORMER
VAPOR LINE
SERVICE VALVE
LIQUID LINE
SERVICE VALVE
COMPRESSOR
TERMINAL BOX
COMPRESSOR
DISCHARGE LINE
Installation Clearances
36"
(914 mm)
Figure 2
*36"
(914 mm)
36"
(914 mm)
*36"
(914 mm)