Troubleshooting the Installation
PRP-3 Alphanumeric LEDs
Single PRP-3 Scenario
Table 4-4
Single PRP-3 Alphanumeric Display LED—Chassis Is Powered ON/Inserting PRP-3
LED Display
02A8/HW
OK/RIO
OK/CPU
SENT/RPT
INIT/MEM
TEST/MEM
LNCH/RMON
RDY/RP
OL-13830-02
The following section discusses the alphanumeric LED messages and the console
output displayed in sequence for a single PRP-3 and for dual PRP-3. The
alphanumeric LED messages help in identifying the state of the route processor
and accordingly troubleshooting the problems faced.
Table 4-4
displays the alphanumeric LED messages and the console output when
the chassis is powered on or when the PRP-3 board is inserted into the slot.
Description or Console Message
Immediately when the board is powered on.
Displays "1.330GHz dual-core MPC8641D Rev 2.1, 532MHz MPXclk".
Displays "Discovering memory in slot DIMM1 ......................... Found 2GB
DIMM
Discovering memory in slot DIMM2 ......................... Found 2GB DIMM"
Displays "Testing low memory ....................................... OK
Loading main ROMMON image ................................ OK
Verifying loaded image ................................... OK
Load succeeded; launching target ......................... OK"
Displays "Cisco ROMMON System Bootstrap, Version 0.16.0 (bld1)
DEVELOPMENT SOFTWARE
Compiled on 08/27/08 at 15:04:49 PDT [BLD-rommon]
Copyright (c) 1994-2008 by Cisco Systems, Inc.
MPC8641D platform with 4 GB of main memory"
DISPLAYS "Loading disk0:c12k-os-mbi-3.8.0.15I/mbiprp-rp.vm (14809672
bytes)... !!!"