ADJUSTING MAXIMUM OUTLET TEMPERATURE
1. Shut the water off at the stop valves.
2. To decrease temperature:
Remove screw and cap and pull handle slowly to remove.
Turn handle counter-clockwise one notch and reinstall onto cartridge.
To increase temperature:
Remove screw and pull handle
slowly to remove.
Turn handle clockwise one notch
and reinstall onto cartridge.
3. Secure handle with screw and put
cap.
4. Open the stop valve.
5. Check water temperature.
**Repeat steps 1-5 if necessary
1. To decrease temprature: turn handle
clockwise.
2. To increase temprature: turn handle
counter-clockwise.
ACCESSING ANG CLEANING THE VALVE
1. Shut the water off at the stop
valves.
2. Disconnect supply hoses.
3. Pull out the filter and clean it
with a brush.
4. Reinstall the clean filter and
connect water supply hoses.
5. Open the stop valves.
ADJUSTING OUTLET TEMPERATRURE
Handle
Screw
Cap
filter
Brush
- 5 -
filter
filter