Do you have a question about the SABER SL-2 and is the answer not in the manual?
Questions and answers
Garry
April 14, 2025
on Pre-soak 2 both pumps run, how do i stop both pre soak and pre-soak 2 pump running at same tim?
1 comments:
Mr. Anderson
April 15, 2025
To stop both pumps from running simultaneously during Pre-soak 2 on the Belanger SABER SL-2, ensure that Pre-Fill is not active. For Pre-Fill to function, both passes must meet specific conditions, such as using the same pump speeds, reclaim settings, tank size, and not having a Purge Time or Dwell Time. By changing one of these conditions—such as using different pump speeds or enabling a Purge Time or Dwell Time—you can prevent Pre-Fill from activating, which will stop both pumps from running at the same time.
Page 1
SL-2 1063 1MANUL294 OPERATOR STATION Belanger, Inc. P.O. Box 5470 PROGRAMMING AND Northville, MI 48167-5470 Customer Service Phone (248) 349-7010 Fax (248) 380-9681 OPERATION MANUAL www.Belangerinc.com REV 03...
Page 3
Do not make additional copies of this manual or electronically transmit it in any form ® whatsoever, in whole or in part, without the prior written permission of Belanger, Inc. The registered trademarks used in this document are the property of their respective owners. The use of such trademarks is ®...
Pressing “Reset All” will clear the values of the total data and package data accumulated since Reset All was last pressed. 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
STORE PATTERN. Now you are to name the Pattern. To use the stored Pattern in the future, press the MAKE CURRENT button. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
• A filled oval indicates that an Output is ON • Some Outputs are namable and will not be the same as names indicated to the left 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
The “DRIVE CODE” field is covered on the next page. Note: FAULT status 255 is for “System Ok”. See Chapter 6 for Fault Information. Note: Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
• Pressing the Auto Capture toggle button alternated between the fields shown below: • Capture: captures (updates) status and conditions at the instant button is pressed 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Chapter 2 General Methods of Using Operator Interfaces Chapter 2 General Methods of Using Operator Interfaces...
Page 19
When done entering the data, press .to return to the original screen. To leave the Data Entry screens without changing data, press 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Page 20
. When done entering the data, press .to return to the original screen. To leave the Data Entry screens without changing data, press Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
• The lower 3 are Exit Operation 1, 2 and 3 • Toggling any to YES will include that feature (Operation) on that package Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
• Both passes are of the same type as selected by Center = “________” in the Application Configuration screen Setup / Advanced Configuration See Chapter 6. 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Pump: This is the pump speed measured in percent for Entrance Operation that is utilizing the 25HP VFD Pump. Only Entrance Operation 1 or Entrance Operation 3 may utilize this pump. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
EFP (End Function Pulse): This is designed to turn on exit functions while wash is still in progress. Each package has a Pass Number and a position from completing that pass that it turns on its EFP. 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Page 28
Max-Time: This is an OFF condition only. It’s a maximum time that a function will stay on once it turns on. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
Enter Door Photo Eye and Exit Door Photo Eye will always be included in door control when system is in AUTO. The additional Enter Photo Eye and the additional Exit Photo Eye may be ENABLED to be included in Automatic Door Control. 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
When in Direct Mode, Input will insert corresponding Package into Loader (i.e. if PACKAGE 1 is displayed, PACKAGE 1 will be loaded into the Loader when Input X15 turns ON). Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
When in Binary Mode each Input is given a value. The Package that is inserted in the Loader is determined by the sum of the Inputs turned ON (have filled ovals). Examples: 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Page 32
Some cell phone providers have systems that require too many buttons and confirmation keys to be pressed making it impossible to send a page automatically. 3-10 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
“4-Application Point” XR has been installed. Not typical. HIGH PRESSURE EXCHANGE TIME: This is the FILL TIME when the High Pressure application switches sides. 3-11 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
LED. If not, use a magnet to shift modes until the mode is correct. If not, see chapter 4 of this document for instructions on how to change the parameters of the Multifunctional Sonar unit. 3-12 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
THERMO SECONDS: This is the run-time of the Thermo-Cycle. It will run the Pump at 15% through the High Pressure path for the set amount of time. 3-13 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Page 36
EMPTY BAY PURGE TIME: This is the amount of time measured in seconds that the machine will use Pulse air to flush the manifolds when the system is “Not in Use”. 3-14 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
Enter pumps via [ENTER OPERATION 1 / ENTER OPERATION 3]: Select which will control the 25HP pump during Entrance Operation. NOTE: Output naming and application configuration need modified to operate ICS instead of SDM Chemical Delivery System. 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Screen Key Screen shows MISCELLANEOUS OUTPUT • 1 – 7 These can not be linked to Entrance and • Exit Operations Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
Page 41
Inches”. in Inches”. Each MISC 1 – 7 Each MISC 1 - 7 have one ON have one OFF position. position. 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Page 42
This toggles to PURGA ALL PASS to purge the entire application. This is to purge while the machine is moving before the On-Board Dryer. This works for AC4 only. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
Page 43
FS 050 FS 100 MISC 2 FS 050 FS 100 Carriage Travel Direction Carriage Travel Direction Carriage Travel Direction Carriage Travel Direction 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Page 44
It will extend the Carriage travel to expand dryer coverage. On-Board Dryer passes must be the last ones in a Package. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
The field to the right of MISC 1 through 8 is • the name that has been assigned to that output Touch the assigned name to edit the • Outputs name 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
0.1 seconds after the vehicle has arrived at the Wash Position and received a Stop Light • After the Rocker Blaster has been ON for an elapsed time of 45 seconds • 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
6. The LED will flash a pulse count identifying the mode that it is in. the model number for the Multifunction Sonar Unit is IRU2005R. The Belanger part number is 1ELECT-SN950. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
This fault occurs when the Carriage Drive signals the carwash controller that it has faulted. BUTTERFLY DRIVE FAULT This fault occurs when the Butterfly Drive signals the carwash controller that it has faulted. 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
Carriage away from the vehicle before attempting to reset the knuckle. If the arm breaks away while attempting to butterfly IN, it will immediately butterfly OUT before attempting to reset the knuckle. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
Page 55
This alarm occurs when Position Resets to ZERO at the Enter Limit but the Carriage Position Error at the time of correction was 30 or greater. 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
COMMUNICATION LEAVE FAULT RETRY COUNT EXCEEDED PR. 24 ALARM FAULT 3 E. 3 FAULT 6 E. 6 FAULT 7 E. 7 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
If it times out you will have to perform the calibration before configuring the network settings. Calibration screen shown on the lower-right. 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
TOUCH ANYWHERE ON SCREEN OR TOUCH CALIBRATE WILL START IN 7 SECONDS Carefully press and briefly hold stylus on the center of the target. Repeat as it moves around screen Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
2: Sent e-mail for Shift, Daily, Weekly Report 3: Sent e-mail of Fault Report 3: NOT Sent e-mail for Shift, Daily, Weekly Report 1MANUL294 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681...
VNC into your favorite search engine to find these web sites. Note: Static ID Address recommended to utilize remote access. E-mail will work with either a static or dynamic IP address. Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL294...
Need help?
Do you have a question about the SABER SL-2 and is the answer not in the manual?
Questions and answers
on Pre-soak 2 both pumps run, how do i stop both pre soak and pre-soak 2 pump running at same tim?
To stop both pumps from running simultaneously during Pre-soak 2 on the Belanger SABER SL-2, ensure that Pre-Fill is not active. For Pre-Fill to function, both passes must meet specific conditions, such as using the same pump speeds, reclaim settings, tank size, and not having a Purge Time or Dwell Time. By changing one of these conditions—such as using different pump speeds or enabling a Purge Time or Dwell Time—you can prevent Pre-Fill from activating, which will stop both pumps from running at the same time.
This answer is automatically generated