Table of Contents

Advertisement

Please check the following before commencing start-up of the unit, as these are important conditions of the
Grant Warranty.
A suitable filter arrangement has been installed. Grant recommends the use of their Mag
one filter which also incorporates a 1200-micron filter.
The system should be flushed, this is especially important if the system is an old gas or oil
system. Flushing should be completed in accordance to BS7593.
Grant recommends a suitable heat transfer is used to give a minimum frost protection of -9.
In order to stop bacterial growth, it is also recommended to use a suitable Biocide if not
included in the heat transfer solution.
A 30lt volumiser or buffer is required for Grant Aerona 3 R32 heat pumps.
The pipe work diameter should be no smaller than 28mm copper. If plastic pipe is used this
should be bigger.
The external mono bloc should be installed on a base suitable for withstanding the weight
of the unit and should be level.
There shall be a proper means of disposal of the condensate, this should be via a drain or
soak away.
The external mono bloc should be positioned so that there is good air flow around the unit.
The minimum clearances are 100mm to the left, 600mm to the right, 300mm behind the
unit and 600mm in front. We would recommend 2m in front.
Antifreeze should be used in the system to give frost protection to minus 9 degrees and if it
does not contain biocide, biocide should be added to protect against bacterial growth.
As part of the commissioning process, it is important that the correct flow rates are achieved for the output of
the unit. Failure to do so, will result in poor performance and protentional faults. The flow rates required are
specified below.
Unit
HPD6R32
HPID10R32
HPID13R32
HPID17R32
*The values above are taken from Grants Manual Sep 2020
W:
www.seconrenewables.com

Warranty

Minimum Flow
Required flow rate @
5lpm
10lpm
15lpm
15lpm
T: 0191 516 6554
Required flow rate @
7A/Water 35
20.22lpm
32.16lpm
40.68lpm
50.88lpm
E:
info@seconrenewables.com
7A/Water 55
11.34lpm
19.26lpm
40.62lpm
27.90lpm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hpd6r32Hpid10r32Hpid13r32Hpid17r32

Table of Contents