SPECIAL MODE

Special mode setting button

b No. 1 - 4, 6 - 8 : While holding down buttons "A", "B" and "C" simultaneously, press the power button to turn on the power.
b No. 5 :
While the power is on, hold down buttons "A" and "B" for at least 3 seconds .
No.
Mode
Version Display
1
(u-COM / DSP Error Display)
PANEL / REMOTE LOCK Selection
2
Mode
PANEL LOCK Mode
2-1
(with Volume)
PANEL LOCK Mode
2-2
(without Volume)
2-3 PANEL LOCK mode is turned off
3
Selecting the Mode for Service-related
3-1 Check the Video/Audio path Mode
3-2 Protection history display mode
3-3 232C Standby Clear Mode
3-4 Operation Info Mode
TUNER STEP Mode
3-5
(E2 model only)
3-6 Remote ID Setup Mode
4
Protection Pass Mode
5
Network Initialization Mode
6
User Initialization Mode
7
Factory Initialization Mode
8
Clearing the Operation Info
h
NOTE : When the volume indicator displays "
To release this special mode, press and hold the "STATUS" and "CURSOR f " buttons for 3 seconds or more while the power is ON. When the volume indicator returns to the normal display, the RS-232C
communication is available.
Button A
Button B
Button C
Displays the version of firmware such as the main firmware or DSP. Errors that have occurred are displayed.
SETUP
OPTION
-
(See
1. Version Display
Start this unit in the PANEL/REMOTE LOCK selection mode so that PANEL LOCK and Remote Lock can be switched between On
and Off. (See
STATUS
INFO
-
PANEL LOCK MODE : No. 2 - 1 - No. 2 - 3
Disables reception from all keys and encoders on the front panel except the power button (including the volume).
-
Disables reception from all keys and encoders on the front panel except the power button and volume encoder.
-
Releases the PANEL LOCK.
-
This is a display for turning on each service-related mode.
ZONE3
STATUS
-
SOURCE
Service-related modes: No. 3-1 - No. 3-4 (See
This is a special mode for service confirmation used during repair work to simplify the confirmation work for the Audio channel /
-
video channel. (See
Displays the protection occurrence history.
-
(See
3-2. Protection History Display
Switches from 232C standby mode to normal standby mode.
-
(See
3-3. 232C Standby Clear
Displays the accumulated operating time of the unit, the number of times the power was switched on, and the number of occur-
-
rences of each protection. (See
Enables reception STEP of the ANALOG TUNER to be changed.
-
(See
3-5. TUNER STEP mode (E2
If there are multiple DENON AV receivers in the same area, this mode prevents other AV receivers from being operated concur-
-
rently with this device. (See
Enables the power to be turned on when protection detection is disabled.
ZONE3
STATUS
CURSOR 0
SOURCE
(See
4. Protection Pass
Network module backup data is initialized.
CURSOR 1
DIMMER
-
(See
5. Network Initialization
Initialize the backup data for the MCU and network module. (Settings for the Installer Setup are not initialized.)
BACK
INFO
-
Initialize the backup data only for MCU.
(Settings for the Installer Setup are initialized) (Network function settings are not initialized.)
CURSOR d
CURSOR f
-
(See
Initializing This
Clear the accumulated operating time of the unit, the number of times the power was switched on, and the number of occur-
OPTION
DIMMER
-
rences of each protection. (See
", the unit has entered a special mode for developers. In this case, the RS-232C communication is not available.
Mode)
2. PANEL / REMOTE LOCK Selection
Mode)
3-1. Selecting the Mode for
Service Path Check
Mode)
Mode)
Mode)
3-4. Operation Info
Mode)
only))
3-6. Remote ID Setup
Mode)
Mode)
Mode)