BLOWER DATA
EL296UH135XV60D BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
1150
Factory Default
1080
985
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
1
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28% and 38% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 450 cfm.
®
EL296UH135XV60D BLOWER MOTOR WATTS (COOLING)
Cooling Speed
1
DIP Switch
Settings
0
0.1
+ Setting
Low
79
108 140 173 200 232 265 290 325 229 250 310 367 396 452 487 529 557 595 639
Med-low 125 157 190 221 264 297 325 355 390 348 385 434 482 532 571 627 655 704 736 793
Cooling
Speed
Med-High 162 199 241 268 303 350 390 426 454 505 532 597 649 689 733 782 826 872 906 942
High
222 250 310 367 396 452 487 529 557 696 733 780 839 910 974 996 1049 1091 1138 1175
Factory Default
Low
63
Med-low
85
115 150 190 210 245 275 310 340 238 261 329 375 427 465 505 548 589 631 670
Cooling
Speed
Med-High 125 159 190 222 260 295 325 358 391 392 426 482 518 581 619 665 699 741 789 826
High
172 210 249 277 326 361 394 444 467 523 561 612 671 716 751 805 867 899 935 986
– Setting
Low
52
Med-low
68
Cooling
Speed
Med-High 89
119 150 192 213 246 279 312 340 265 297 352 403 439 489 534 574 605 651 699
High
123 154 191 216 261 296 331 353 384 392 426 482 518 581 619 665 699 741 789 826
First Stage Heating Speed - cfm
1770
1680
1610
1485
1440
1360
1285
1215
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
1310
1210
1095
Motor Watts @ Various External Static Pressures - in. wg.
First Stage
0.2
0.3
0.4
0.5
93
119 144 173 199 230 258 284 172 210 249 277 326 361 394 444 467 513 545
78
106 129 148 177 201 228 258 123 154 191 216 261 296 331 353 384 421 459
98
124 150 184 207 241 268 294 172 214 244 289 334 368 408 454 491 523 564
HEATING
COOLING
High
Low
2
1440
1610
1640
1330
1475
1480
1210
1315
1330
0.6
0.7
0.8
0
0.1
Page 24
Second Stage Heating Speed - cfm
2125
2015
1935
1855
1740
1650
1565
1460
Second Stage Cooling Speed - cfm
Medium-Low
Medium-High
1840
1660
1500
Second Stage
0.2
0.3
0.4
0.5
0.6
High
2
2000
2250
1885
2035
1675
1885
0.7
0.8
0.9
1.0