ASSEMBLY INSTRUCTIONS FOR NG
NG and LP conversion:
A.Change the orifice
B.Connect the natural gas gray pipe
• This kit converts your pizza oven for natural gas use at 7 inch
water column supply pressure. Verify supply pressure with
your local gas company. If supply pressure is different than 7
inch, contact a certified plumber for assistance.
• Placing markings provided in the kit in the appropriate
location on the converted appliance.
Orifice size: NG Main burner=1.52mm, NG Rear burner=1.32mm
Propane Main burner=1.08mm, Propane Rear burner=0.95mm
LP TRANSFORMATION PART LIST
LP Main burner
1.08 mm orifice×1
14,000BTU
LP Rear burner
0.95 mm orifice×1
10,000BTU
LP hose assembly
Inlet manifold pressure
For Propane-----11 inch water column
For NG-----7 inch water column
FOR MORE DETAILS AND INFORMATION, PLEASE VISIT OUR WEBSITE WWW.KUCHT.COM
NG TRANSFORMATION PART LIST
NG Main burner
1.52 mm orifice ×1
14,000BTU
(NOT INCLUDED)
NG Rear burner
1.32 mm orifice×1
10,000BTU
(NOT INCLUDED)
NG hose assembly
(NOT INCLUDED)
Coversion Kit label