Advertisement

Quick Links

INSTALLATION
OPERATION
MAINTENANCE
Models:
TCH024C1
TCH030C1
TCH048F1
TCH036C1
TCH060F1
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work.
WARNING:
ALL phases of this installation must comply with NATIONAL,
STATE, and LOCAL CODES.
These instructions do not purport to cover all variations in
systems nor to provide for every possible contingency to be
met in connection with installation. Should further information be
desired or necessary or should particular problems arise which are
not covered sufficiently for the purchaser's or installer's needs or
purposes, the matter should be referred to the manufacturer.
!
THIS INFORMATION IS FOR USE BY INDIVIDUALS HAVING
ADEQUATE BACKGROUNDS OF ELECTRICAL AND MECHANI-
CAL EXPERIENCE. ANY ATTEMPT TO REPAIR A CENTRAL
AIR CONDITIONING PRODUCT MAY RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE. THE MANUFACTURER
OR SELLER CANNOT BE RESPONSIBLE FOR THE INTERPRE-
TATION OF THIS INFORMATION, NOR CAN IT ASSUME ANY
LIABILITY IN CONNECTION WITH ITS USE.
!
Reconnect all grounding devices.
All parts of this product that are capable of conducting electri-
cal current are grounded. If grounding wires, screws, straps,
clips, nuts, or washers used to complete a path to ground are
removed for service, they must be returned to their original
position and properly fastened.
The manufactuter has a policy of continuous product and product data improvement, and it reserves the right to change design and
specification without notice.
© 2009 Trane
TCH042C1
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
WARNING
CAUTION
Packaged Cooling
Electric Heat
Over/Under
2, 2-1/2, 3, 3-1/2, 4, 5 Tons
2, 2-1/2, 3, 3-1/2 Tons Shown
!
CONTAINS REFRIGERANT!
SYSTEM CONTAINS OIL AND REFRIGERANT UNDER
HIGH PRESURE. RECOVER REFRIGERANT TO RELIEVE
PRESSURE BEFORE OPENING SYSTEM
proper procedures can result in personal illness or injury or
severe equipment damage.
TCH-IOM-10
18-AB33D6-10
CAUTION
. Failure to follow
04/09

Advertisement

Table of Contents
loading

Summary of Contents for Trane TCH024C1

  • Page 1 The manufactuter has a policy of continuous product and product data improvement, and it reserves the right to change design and specification without notice. © 2009 Trane 04/09...
  • Page 2: General Information

    General Information These instructions cover installation, operation, and mainte- Power Supply nance of all single package TCH024-060 air conditioning units. The power supply must be adequate for the unit and any For an easy and orderly installation, follow the sequence of supplementary electric heaters, if added.
  • Page 3 TCH024, 030, 036, 042C Unit Dimensions and Clearances INSTALLATION / SERVICE CLEARANCE BACK 48.0" LEFT SIDE 24.0" RIGHT SIDE 36.0" 36.0" COIL DIMENSION (IN) APPROX. CORNER WTS - LBS. TOTAL MODEL WEIGHT LBS. TCH024C TCH030C TCH036C TCH042C Dwg. No. D673590 REV. 0 Page 3...
  • Page 4 TCH048, 06F1 Unit Dimensions and Clearances INSTALLATION / SERVICE CLEARANCE BACK 48.0" LEFT SIDE 24.0" RIGHT SIDE 36.0" 36.0" APPROX. CORNER WTS - LBS. TOTAL MODEL WEIGHT LBS. TCH048F TCH060F Page 4...
  • Page 5: Installation Applications

    Installation Applications Roof Top DISCHARGE AIR For roof top installations, the roof must have sufficient struc- tural strength to support the load. FHA approved construction and local codes are normally adequate provided the roof joists and rafters have a proportionally distributed load. See Figure 2. The unit should be positioned for recommended clearances as previously outlined under "Location and Recommendations"...
  • Page 6: Electrical Wiring

    Electrical Wiring Electrical Wiring ▲ Recommended wire sizes and lengths for installing the unit WARNING: TO PREVENT INJURY OR DEATH thermostat are provided in Table 1: Thermostat Wire Size DUE TO ELECTRICAL SHOCK OR CONTACT WITH MOVING and Maximum Length. The total resistance of these low PARTS.
  • Page 7: Typical Field Wiring Diagram

    Typical Field Wiring Diagram TCH024, 030, 036, 042C and TCH048, 060F Units (Cooling Only) B757385 TCH024, 030, 036, 042C and TCH048, 060F Units (With Supplementary Heaters) Page 7...
  • Page 8: Sequence Of Operation

    Sequence of Operation Start-Up The unit's operation is controlled by the remote room thermostat. Pre-Start Quick Check List Once the thermostat is placed in the COOL position, the unit's •Is the unit properly and securely located and level with the operation is automatic.
  • Page 9: Troubleshooting Chart

    Start-Up Start-Up room temperature. The outdoor fan motor, compressor, and evaporator fan motor will operate automatically. Starting the Unit in the Heating Mode Operating Pressures After the unit has operated in the cooling mode for a short time, NOTE: See the section on "Sequence of Operation" for a descrip- install pressure gauges on the gauge ports of the discharge and tion of the heating operating sequence.
  • Page 10: Maintenance

    Maintenance Routine Maintenance by Owner In addition, your serviceman should inspect: •unit duct connections to see that they are physically sound and sealed to You can do some of the periodic maintenance functions for your TCH unit the unit casing yourself.
  • Page 11 Base Limited Warranty Packaged Air Conditioner and Packaged Heat Pump TCK, TCH, WCK, WCH (Parts Only) Models Less Than 20 Tons for Residential Use* This limited warranty is provided by the manufacturer to the original purchaser and to any succeeding owner of the real property to which the Packaged Air Conditioner or Packaged Heat Pump (packaged unit) is originally affixed, and applies to products purchased and retained for use within the U.S.A.
  • Page 12: Models Less Than 20 Tons For Commercial Use

    Residential Systems 6200 Troup Highway, Tyler, TX 75707 Attention: Consumer Relations Or visit our website: www.trane.com/residential TW-1001-3308 * This warranty is for commercial usage of said equipment and not applicable when the equipment is used for a residential application. Commercial use is any application where the end purchaser uses the product for other than personal, family or household purposes.

This manual is also suitable for:

Tch042c1Tch030c1Tch048f1Tch036c1Tch060f1

Table of Contents