Champion Global Power Equipment 200967 Operator's Manual

Champion Global Power Equipment 200967 Operator's Manual

3500w dual fuel portable generator
Hide thumbs Also See for 200967:

Advertisement

Quick Links

OPERATOR'S MANUAL
MODEL #200967
3500W DUAL FUEL PORTABLE GENERATOR
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
Patent pending.

Advertisement

Table of Contents
loading

Summary of Contents for Champion Global Power Equipment 200967

  • Page 1 OPERATOR'S MANUAL MODEL #200967 3500W DUAL FUEL PORTABLE GENERATOR SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury. This manual should remain with the product.
  • Page 2 CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.
  • Page 3: Table Of Contents

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR TABLE OF CONTENTS TABLE OF CONTENTS Maintenance ..........Cleaning the Generator .......... Introduction ...........
  • Page 4: Introduction

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR INTRODUCTION INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to (CPE) product. CPE designs, builds, and supports all of our possible dangers.
  • Page 5: Important Safety Instructions

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS DANGER Operate equipment with guards in place. WARNING Rotating parts can entangle hands, feet, hair, clothing and/or Cancer and Reproductive Harm accessories. Traumatic amputation or severe laceration can result.
  • Page 6 200967 - 3500W DUAL FUEL PORTABLE GENERATOR IMPORTANT SAFETY INSTRUCTIONS WARNING CAUTION Spark from removed spark plug wire can result in fire or Start the generator and allow the engine to stabilize before electrical shock. connecting electrical loads. Connect electrical equipment in the off position, and then turn When servicing the generator: them on for operation.
  • Page 7: Fuel Safety

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR IMPORTANT SAFETY INSTRUCTIONS Fuel Safety DO NOT pump gasoline directly into the generator at the gas station. Use an approved container to transfer the fuel to the generator. DANGER DO NOT overfill the gasoline tank.
  • Page 8: Safety And Dataplate Labels

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR IMPORTANT SAFETY INSTRUCTIONS Safety and Dataplate Labels These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.
  • Page 9: Safety Symbols

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR IMPORTANT SAFETY INSTRUCTIONS Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 10: Operation Symbols

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR IMPORTANT SAFETY INSTRUCTIONS Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 11: Quick Start Label Symbols

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR IMPORTANT SAFETY INSTRUCTIONS Quick Start Label Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 12: Controls And Features

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR CONTROLS AND FEATURES CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1.
  • Page 13: Control Panel

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR CONTROLS AND FEATURES Control Panel 1. Intelligauge – Four mode digital meter for displaying voltage, Fuel Select Dial frequency, run time, and total run time. 2. Circuit Breakers (Push Reset) – Protects the generator against electrical overloads.
  • Page 14: Intelligauge

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR CONTROLS AND FEATURES Intelligauge Four mode digital meter for displaying voltage, frequency, run time, and total run time. MODE DESCRIPTION Output voltage of the generator. Voltage (V) Example: 120 volts Output frequency in hertz.
  • Page 15: Parts Included

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR CONTROLS AND FEATURES Parts Included Accessories 6.5 ft. (2 m) LPG Hose with Regulator......Engine Oil ........
  • Page 16: Assembly

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR ASSEMBLY ASSEMBLY Add Engine Oil Your generator requires some assembly. It must be properly WARNING serviced with fuel and oil before operation. DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil.
  • Page 17: Add Fuel: Gasoline

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR ASSEMBLY 4. Check engine oil level at every use and add as needed. Add Fuel: Gasoline Use clean, fresh, regular unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume.
  • Page 18: Add Fuel: Propane (Lpg)

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR ASSEMBLY Add Fuel: Propane (LPG) CAUTION Connecting an LPG cylinder Use unleaded gasoline with a minimum octane rating of 87 1. Make sure the fuel select dial is in the “ENGINE STOP” and an ethanol content of 10% or less by volume.
  • Page 19: Grounding

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR ASSEMBLY Grounding NOTICE Your generator must be properly connected to an appropriate – The LPG hose included with this unit works with standard ground to help prevent electric shock. 20, 30, and 40 pound LPG tanks.
  • Page 20: Operation

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR OPERATION OPERATION WARNING Do not expose to rain or use in damp locations. Generator Location Keep all objects a minimum of 5 feet (1.5m) away from the generator at all times. Heat from the muffler surface and WARNING exhaust gas stream can ignite combustible materials.
  • Page 21: Starting The Engine: Propane (Lpg)

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR OPERATION NOTICE For gasoline starting in cold ambient temperature < 59°F (15°C), the choke must be in 100% of the “CHOKE” position for recoil cord procedures. Do not over-choke. As soon as engine starts, gradually move the choke lever to the “RUN”...
  • Page 22: Connecting Electrical Loads

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR OPERATION 7. Move the choke to the “CHOKE” position. NOTICE If the engine starts but does not run make certain that the generator is on a flat, level surface. The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold.
  • Page 23: Do Not Overload Generator

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR OPERATION 1. Start the generator with no electrical load attached. WARNING 2. Allow the engine to run for several minutes to get up to Always remember to plug your appliances directly into the temperature.
  • Page 24: Moving The Generator

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR MAINTENANCE 4. If operating on LPG, close valve on LPG cylinder. to the increased enrichment of the air fuel ratio. Other high altitude issues can include hard starting, increased fuel consumption and spark plug fouling.
  • Page 25: Cleaning The Generator

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR MAINTENANCE 2. Allow the oil to drain completely into an appropriate container. NOTICE For Emission control devices and systems, read and understand your responsibilities for service as stated in the Emission Control Warranty Statement of this manual.
  • Page 26: Cleaning The Air Filter

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR MAINTENANCE 4. Make certain the spark plug gap is 4. Carefully remove the carbon deposits from the spark arrestor 0.024-0.031 in. (0.6-0.8 mm). screen with a wire brush. SPARK PLUG GAP 5. Refer to the spark plug types in Specifications when replacing the plug.
  • Page 27: Maintenance Schedule

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR STORAGE Maintenance Schedule STORAGE Follow the service intervals indicated in the following maintenance DANGER schedule. Service your generator more frequently when operating in adverse Gasoline vapors are highly flammable and extremely explosive. conditions.
  • Page 28: Long Term Storage (Over 1 Year)

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR STORAGE 5. Option 1: Drain Gasoline from Carburetor 4. When gasoline stops flowing from the carburetor, replace and tighten the carburetor drain bolt and be sure to properly 5a. Turn the fuel select dial to the “ENGINE STOP” position dispose of the drained gasoline according to local regulations and allow generator to cool completely before continuing.
  • Page 29: Specifications

    200967 - 3500W DUAL FUEL PORTABLE GENERATOR SPECIFICATIONS SPECIFICATIONS Recommended Engine Oil Type 10W-30 Generator Specifications 5W-30 10W-40 Generator Model ......... ..

Table of Contents