Pn 15 Startup DC braking voltage
By proper tuning of this parameter, motor can start
normally from fully stop state without any difficult caused
by motor's free motion and rotate direction.
Pn 16 Startup DC braking time
DC braking time before motor startup to ensure that motor
is started from fully stop state.
Pn 17 Stop DC braking voltage
Braking voltage during DC braking period to ensure that
motor is fully stopped in brake time.
Pn 18 Stop DC braking time
DC braking time to prevent the slide move after stopping.
Pn 19
Source of multi-segment speed 0
Multi-segment speed mode 0-segment frequency source:
Pn 20
Multi-segment speed 1 frequency
Multi-segment speed mode 1-segment frequency
Pn 21
Multi-segment speed 2 frequency
Multi-segment speed mode 2-segment frequency
Pn 22
Multi-segment speed 3 frequency
Multi-segment speed mode 3-segment frequency
:1V—100V
:000.00S—650.00S
:1V—100V
:000.00S—650.00S
1 Potentiometer
3 External 0-5V signal
5 External 0-20mA signal
:1—5
2 Panel button
4 External 0-10V signal
:000.10 Hz—400.00Hz
:000.10 Hz—400.00Hz
:000.10 Hz—400.00Hz