Chapter 7 Description Of Configure Parameters - HKS VFD Drive A2 Series User Manual

Table of Contents

Advertisement

A2 VFD
(0.75-30kW)

Chapter 7 Description of Configure Parameters

Pn 01
Default display content:1——30000
RUN: 1 means it will display runtime frequency
STOP:it will display frequency given by external signal.
Pn 02
Initial startup frequency by panel or other method Range:
000.01Hz-400.00Hz,the initial panel data and
Pn 03
Source of runtime frequency with range:1—7
1 Potentiometer
3 External 0-5V signal
5 External 0-20mA signal
7 Multi-segment signal
Pn 04
Source of runtime command with range
1 Panel button control
Pn 05
clockwise / anticlockwise disable with range
1 clockwise enable only
3 clockwise / anticlockwise enable
Pn 06
Method to stop VFD with range
1 stop by itself
Pn 07
Start again by external signal with range
1 disable
Description: when the power on the external operation of
the signal is allowed to start effectively.
Pn 08
Acceleration time with range
Accelerate time (from 0Hz to Pn10).
Otherwise, it displays motor's synchronization speed. 2——
30000 is motor synchronization speed
external signal frequency during startup
12
2 Panel button
4 External 0-10V signal
6 External digital signal
:1—2
2 External signal control
:1—3
2 anticlockwise enable only
:1—2
2 stop by deceleration
:1—2
2 enable
:000.01S-650.00S
.

Advertisement

Table of Contents
loading

Related Products for HKS VFD Drive A2 Series