Page 2
Hasselblad A/S assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. Hasselblad A/S assumes no responsibility or liability for loss or damage incurred during or as a result of using Hasselblad software or products.
• When you turn on the scanner, the drum will roll to the load position, if it is not there already. Do not touch the scanner while the drum is rotating. • Do not place your fingers or any other object into the scanner while it is connected to power.
“Software Reference” manual, that comes with the FlexColor software. • Screen resolution of 800 x 600 pixels with true colors (24-bits). • Mouse or other pointing device. • FireWire interface. User's Guide - Flextight 949 Hardware Reference - Flextight 949 System Requirements...
Front Panel Figure 1: Front panel features of Flextight 949 Feed Table: must be in lower position for normal scanning. When scanner is not in use you can turn it to upright position flushing with the scanner front to protect it from dust etc. Adjust to horizontal position when using the 35 mm slide mount holder (see page 15).
Hardware Reference - Flextight 949 Back Panel & Connectors Back Panel & Connectors Figure 2: Back panel features of Flextight 949 Power Cable Socket: plug the power cable into this socket. FireWire Interface Sockets: plug a FireWire cable (max. 6 m) here and connect it to your computer.
Cut-Away View Figure 3: Cut-away view of Flextight 949 CCD Housing: movable platform holding the CCD sensor. Positioning Lead Screws: for positioning of the CCD housing and optics housing for the appropriate resolution and original size. Optics Housing: movable platform holding the optics which focuses the image of the original on the CCD-sensor.
Avoid using the scanner in areas where there is a high level of dust. Electrical Requirements The Flextight 949 power supply requires a mains voltage of between 100 and 240 V AC at a frequency of 50 to 60 Hz. This is within the normal wall-socket power standards of most countries.
IMPORTANT: Make sure that the wall socket you are planning to use meets the electrical requirements outlined earlier. Plug the Flextight 949 power supply into a wall socket. Note that the power supply may emit a low buzzing sound when plugged in. This is normal and will not damage the power supply or scanner.
If not already done, turn the feed table (A) to normal position. Press the red power button (F) on the front of the scanner to switch it on. The green light (G) starts flashing. This means that no firmware has been downloaded yet.
Page 17
NOTE! Each original holder has it's own unique identification code (a combination of small rectangular holes at the holder's leading edge). These codes, combined with the scanner's ability to detect the feed table position, ensure that the scanner will not operate unless the feed table position matches the selected original holder.
Page 18
Hardware Reference - Flextight 949 Operating Instructions ...continued Lay the top layer of the holder down flat over the original. • For transparency holders, the top layer is magnetic, which will hold the original fast. • For the reflective holder, note the four metal pegs (the top two are shown as A and C in Figure 5 below);...
The focus calibration is stored in the scanners flash PROM, so it is preserved when you move the scanner to a new computer. See "Focus Calibration" on page 21 for more information.
Focus Calibration The Flextight 949 scanner uses an adjustable zoom and focus mechanism to optimize its scanning resolution for each of the original formats it can handle. If you suspect your scans are not as sharp as they should be, then you may need to calibrate your scanner.
Use procedure below to make White Calibration: Find the white calibration sheet that came with your scanner. It is a square white piece of paper (219 x 219 mm (8.6" x 8.6")).
Page 23
Figure 6: Positioning the white calibration sheet on the reflective holder Click on Calibrate. The scanner will take several scans of the white target. The process will take about eight minutes. User's Guide - Flextight 949 Hardware Reference - Flextight 949...
Page 24
Hardware Reference - Flextight 949 The Light Tubes PULL OUT PRESS à PRESS Figure 7: Replacing the Light Tubes PULL OUT User's Guide - Flextight 949...
The Light Tubes General The Flextight 949 contains two light tubes: one for illuminating reflective originals from above, the other for shining light through transparencies from below. NOTE! The two lamps are of different types and are not interchangeable. Replacing the Light Tubes If your scans are suddenly coming out black (or all white if you are scanning negatives), then one of your light tubes may be defective.
Page 26
Hardware Reference - Flextight 949 The Light Tubes PULL OUT PRESS à PRESS Figure 7: Replacing the Light Tubes PULL OUT User's Guide - Flextight 949...
Page 27
NOTE! When mounting the front panel (A) make sure to give it a firm push at the bottom to click it properly into position. 15. Turn on the scanner and check function of the new tube. User's Guide - Flextight 949...
Cleaning the External Surface of the Scanner Cleaning the External Surface of the Scanner If the external surface of the scanner becomes dirty, then clean it with a damp cloth. Be careful not to get any moisture inside the scanner or on any of the connectors.
Hardware Reference - Flextight 949 FCC Notice FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
The undersigned, hereby declare that the equipment specified above conforms to the above Directives and Standards. Place ... Date ... Full name ... Position ... User's Guide - Flextight 949 Hardware Reference - Flextight 949 CE - Declaration of conformity 89/336/EEC amended by 92/31/EEC, 93/68/EEC. 91/157/EEC. C73/23/EEC amended by 93/68/EEC.
Need help?
Do you have a question about the Flextight 949 and is the answer not in the manual?