Chassis 474-BODY
4.5.9
6-Slot Chassis 474-BODY6R-R1
Excessive current draw
The 6-slot chassis with an internal power supply unit is not equipped with a fuse on its primary side.
The protection against excessive current draw has to be provided by the electrical installation of the building.
Power supply voltage too low
With chassis 474-BODY6R-R1 a redundant power supply voltage is possible up to a current of maximum 5 A
(modules inclusive connected periphery). If the power supply voltage of the internal power supply unit fails, the
device's power supply voltage is secured via the 5 V external power supply unit.
If there is no redundant power supply voltage and the current is above 5 A, the device is not supplied with sufficient
power supply voltage and fails.
Note the maximum current draw of the chassis (see chapter 6.3, page 66).
With a current of more than 5 A, use an external power supply unit. In this case, redundancy is inapplicable.
Fig. 11
Interface side chassis 474-BODY6R-R1
1
Slot 1
2
Slot 2
3
Slot 3
4
Slot 4
NOTICE
NOTICE
5
Slot 5
6
Slot 6
7
Power supply voltage 2, DC
8
Power supply voltage 1, AC
Description
19