Temperature
Relative Humidity
Pressure
Door & Window
Wall
Fire Protection
Power
2.5 Grounding Requirement
All function modules' good grounding is the basis of reliability and stability of devices. Also, they
are the most important guarantee of lightning arresting and interference rejection. Therefore, the
system must follow this rule.
Grounding conductor must adopt copper conductor in order to reduce high frequency impedance,
and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device's frame should be no less than
2
25 mm
.
2.6 Frame Grounding
All the machine frames should be connected with protective copper strip. The
grounding wire should be as short as possible and avoid circling. The area of the
conduction between grounding wire and grounding strip should be no less than
2
25mm
.
2.7 Device Grounding
Connecting the device's grounding rod to frame's grounding pole with copper wire.
Website: http://www.baudcom.com.cn
installing air-conditioning is recommended
20%~80% sustainable 10%~90% short time
86~105KPa
Installing rubber strip for sealing door-gaps and dual level glasses
for window
It can be covered with wallpaper, or brightness less paint.
Fire alarm system and extinguisher
Requiring device power, air-conditioning power and lighting
power are independent to each other. Device power requires AC
110V±10%, 50/60Hz or AC 220V±10%, 50/60Hz. Please
carefully check before running.