Napoleon Vittoria GD19-2 Installation And Operation Manual page 23

Table of Contents

Advertisement

Available languages

Available languages

3.2.2 top vent (minimum clearance to combustible enclosures)
20"
508mm
53 1/8"
1349mm
33 1/8"
841mm
* See "venting requirements" section
Horizontal Vent Sections: A minimum clearance of 1" (25mm) at the bottom and sides, and 2" (51mm) at the
top of the vent pipe in all horizontal runs to combustibles is required except for clearances in appliance enclosure
which must be a minimum of 6" (152mm). Use firestop spacer W010-1777 (supplied).
Vertical Vent Sections: A minimum of 1" (25mm) all around the vent pipe on all vertical runs to combustibles is
required. Use firestop spacer W500-0096 (not supplied).
The appliance requires a minimum enclosure / ceiling height of 53 1/8" (134.9cm) for top vent. For temperature
requirements, the enclosure space around and above the appliance must be left unobstructed.
** When terminating vertically on a top vented appliance, the height of the enclosure can be reduced to 39 1/8"
(99.3cm).
COMBUSTIBLE
1/2" 13mm
6" 152mm
1" 25mm
1" 25mm
NON-COMBUSTIBLE
BRICK
0" IF NON-COMBUSTIBLE
2" 51mm
FINISHING IS USED SUCH
AS BRICK AND STONE.
1" 25mm
43 1/8"
1095mm
MINIMUM
PLUS RISE *
framing
EN
23
W415-2355 / 11.13.19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vittoria gd19n-2Vittoria gd19p-2

Table of Contents