F.2 Enabling NVMe RAID
RAID for NVMe SSDs must be enabled through the UEFI BIOS.
1. Install the patch as described in the Restrictions and Requirements section on a
previous page.
2. Reboot the server.
3. Press [DEL] key to enter BIOS.
4. Switch to Advanced > Chipset Configuration > North Bridge > IIO Configuration >
Intel® VMD Technology > CPU1 & CPU2.
5. Enable the VMD according to the following rules.
For U.2 NVMe, enable all the sub-items under each PStack, based on the your model
server:
Model
1029U-T
6019U-TN4
2029U-T
2029U-E1C
2029UZ-T
6029U-T
6029U-E1C
6029UZ-T
1029U-TN10
2029U-TN24
1029UZ-TN20
2029UZ-TN20
1029U-E1C
6019U-T
For M.2 NVMe or NVMe AIC, enable the VMD according to which AOC card/slot it used.
Examples for some U.2 configurations follow.
VMD BIOS Setting for Ultra Servers
CPU1
VMD Config for PStack0
VMD Config for PStack0
VMD Config for PStack1
VMD Config for PStack2
VMD Config for PStack1
VMD Config for PStack0
VMD Config for PStack1
VMD Config for PStack2
VMD Config for PStack0
VMD Config for PStack1
VMD Config for PStack2
U.2 NVMe not supported
163
Appendix F CPU-Based RAID for NVMe
CPU2
not needed
VMD Config for PStack1
VMD Config for PStack1
VMD Config for PStack2
VMD Config for PStack2
VMD Config for PStack0
VMD Config for PStack1
VMD Config for PStack2
VMD Config for PStack0
VMD Config for PStack2

Advertisement