Summary of Contents for Supermicro SuperServer 2029P-C1RT

  • Page 1 SuperServer ® 2029P-C1R 2029P-C1RT USER’S MANUAL Revision 1.0a...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Warnings Special attention should be given to the following symbols used in this manual.
  • Page 4: Table Of Contents

    SuperServer 2029P-C1R(T) User's Manual Contents Chapter 1 Introduction 1.1 Overview ..........................8 1.2 Unpacking the System ......................8 1.3 System Features ........................9 1.4 Server Chassis Features ....................10 Control Panel ........................10 Front Features ........................11 Rear Features ........................12 1.5 Motherboard Layout ......................13 Chapter 2 Server Installation 2.1 Overview ..........................17 2.2 Preparing for Setup ......................17 Choosing a Setup Location ....................17...
  • Page 5 Preface Chapter 3 Maintenance and Component Installation 3.1 Removing Power .......................26 3.2 Accessing the System ......................27 3.3 Motherboard Components ....................28 Processor and Heatsink Installation ..................28 The Xeon Scalable Processor ..................28 Overview of the Processor Socket Assembly ..............29 Heatsinks ........................30 Overview of the Processor Heatsink Module (PHM) .............31 Assembling the Processor Package ................32 Assembling the Processor Heatsink Module (PHM) .............34 Preparing the CPU Socket for Installation..............35...
  • Page 6 SuperServer 2029P-C1R(T) User's Manual Chapter 4 Motherboard Connections 4.1 Power Connections ......................54 4.2 Headers and Connectors ....................55 Control Panel ........................59 Data Cables ........................61 4.3 Input/Output Ports and Interface Buttons ................62 4.4 Jumpers ..........................63 4.5 LED Indicators ........................65 Chapter 5 Software 5.1 OS Installation ........................67 Installing the Windows OS for a RAID System ..............67 Installing Windows to a Non-RAID System ..............67...
  • Page 7 Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 8: Chapter 1 Introduction

    SuperServer 2029P-C1R(T) User's Manual Chapter 1 Introduction 1.1 Overview The SuperServer 2029P-C1R(T) is an all-purpose server system in the SC213AC-R1K23LPB chassis, using an X11DPi-N(T) motherboard for memory, CPU, storage, or network intensive applications. It will serve well in data centers, government labs, or business enterprises, for cloud and virtualization, simulation, automation, hosting and storage.
  • Page 9: System Features

    Chapter 1: Introduction 1.3 System Features The following table provides an overview of the main features of the 2029P-C1R(T) server Refer to Appendix C for additional specifications. System Features Motherboard X11DPi-N(T) Chassis SC213AC-R1K23LPB Supports dual Intel 81xx/61xx/51xx/41xx/31xx series (Socket P0) processors which offer Intel UltraPath Interconnect (UPI) of up to 10.4 GT/s Memory Supports up to 2 TB of 3DS LRDIMM/LRDIMM/3DS RDIMM/RDIMM/NV-DIMM DDR4 (288-pin) ECC...
  • Page 10: Server Chassis Features

    SuperServer 2029P-C1R(T) User's Manual 1.4 Server Chassis Features Control Panel The is a system control panel on the front outside edge of the chassis that houses power buttons and status monitoring lights. Figure 1-1. Control Panel Control Panel Features Item Feature Description The main power switch applies or removes primary power from the...
  • Page 11: Front Features

    Chapter 1: Introduction Information LED Status Description Continuously on and An overheat condition has occurred. (This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan. Power failure, check for a non-operational power Blinking red (0.25Hz) supply.
  • Page 12: Rear Features

    SuperServer 2029P-C1R(T) User's Manual Rear Features The illustration below shows the features included on the rear of the chassis. Figure 1-3. Chassis Rear View Rear Chassis Features Item Feature Description Power Supplies Redundant power modules I/O ports Described in this manual, Section 4.3 PCI Slots Five low-profile PCIe slots (two others are not usable)
  • Page 13: Motherboard Layout

    Chapter 1: Introduction 1.5 Motherboard Layout Below is a layout of the X11DPi-N(T) with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 4. I P M I L A N SLOT2...
  • Page 14 Gigabit LAN/10G LAN Ethernet Ports on the IO back panel (10G LAN ports on LAN1/LAN2 X11DPi-NTX11DPi-N(T) only) S-SATA0-3 S-SATA 3.0 iPass header supported by the Intel SCU S-SATA Ports with built-in power pins and with support of Supermicro SuperDOM (Disk On Module) S-SATA4/S-SATA5 devices SLOT1/SLOT3 PCI-Express 3.0 X8 Slots supported by CPU1 SLOT2 PCI-Express 3.0 X16 Slot supported by CPU1...
  • Page 15 Chapter 1: Introduction Connector Description USB0/1 Back panel USB 2.0 Ports USB2/3 Front Accessible USB 2.0 Header USB4/5 Back panel USB 3.0 Ports USB6 Type A USB 3.0 Header USB7/8 Front Accessible USB 3.0 Header VGA Port Description State: Status UID (Unit Identifier) LED Solid Blue: Unit identified Onboard Power LED...
  • Page 16 SuperServer 2029P-C1R(T) User's Manual VCCP0 VCCP1 DDR4 DDR4 SLOT 2 PCI-E X16 G3 (LANE REVERSE) PCI-E X8 G3 PCI-E X16 G3 SLOT 1 PCI-E X8 G3 PCI-E X16 G3 SLOT 4 PCI-E X16 G3 2 x NVME PCI-E X8 G3 SLOT 3 (LANE REVERSE) DMI3...
  • Page 17: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 4 for details on installing those specific components. Caution: Electrostatic Discharge (ESD) can damage electronic components.
  • Page 18: Server Precautions

    SuperServer 2029P-C1R(T) User's Manual • In single rack installations, stabilizers should be attached to the rack. In multiple rack in- stallations, the racks should be coupled together. • Always make sure the rack is stable before extending a server or other component from the rack.
  • Page 19: Circuit Overloading

    Chapter 2: Server Installation Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  • Page 20: Installing The Rails

    SuperServer 2029P-C1R(T) User's Manual 2.3 Installing the Rails This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly from the instructions provided.
  • Page 21: Releasing The Inner Rail

    Chapter 2: Server Installation Releasing the Inner Rail Each inner rail has a locking latch. This latch prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing. To mount the rail onto the chassis, first release the inner rail from the outer rails. 1.
  • Page 22: Installing The Inner Rails

    SuperServer 2029P-C1R(T) User's Manual Installing the Inner Rails Begin the rack mounting procedure by installing the inner rails to the chassis. 1. Identify the left and right inner rails. They are labeled. 2. Place the inner rail firmly against the side of the chassis, aligning the hooks on the side of the chassis with the holes in the inner rail.
  • Page 23: Installing The Outer Rails Onto The Rack

    Chapter 2: Server Installation Installing the Outer Rails onto the Rack 1. Press upward on the locking tab at the rear end of the middle rail. 2. Push the middle rail back into the outer rail. 3. Hang the hooks on the front of the outer rail onto the square holes on the front of the rack.
  • Page 24: Installing The Server Into A Rack

    SuperServer 2029P-C1R(T) User's Manual 2.4 Installing the Server into a Rack Once rails are attached to the chassis and the rack, you can install the server. Caution: Heavy! Use two or more people or a lift to install the server. 1.
  • Page 25: Removing The Chassis From The Rack

    Chapter 2: Server Installation Removing the Chassis from the Rack Caution! It is dangerous for a single person to off-load the heavy chassis from the rack without assistance. Be sure to have sufficient assistance supporting the chassis when removing it from the rack.
  • Page 26: Chapter 3 Maintenance And Component Installation

    SuperServer 2029P-C1R(T) User's Manual Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 27: Accessing The System

    Chapter 3: Maintenance and Component Installation 3.2 Accessing the System You can access some chassis components, such as fans, by removing the cover. Removing the Chassis Cover 1. Remove the screw on each side of the chassis. 2. Depress the release buttons and slide the cover back and off. Caution: Except for short periods of time, do not operate the server without the cover in place.
  • Page 28: Motherboard Components

    When receiving a motherboard without a processor pre-installed, make sure that the plastic CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro website for updates on CPU support. The Xeon Scalable Processor SKX Processor SKX-F Processor Figure 3-2.
  • Page 29: Overview Of The Processor Socket Assembly

    Chapter 3: Maintenance and Component Installation Overview of the Processor Socket Assembly The processor socket assembly contains 1) the Intel SKX(-F) CPU, 2) the narrow processor clip, 3) the dust cover, and 4) the CPU socket. 1. SKX (-F) CPU (for the non-F model) 2.
  • Page 30: Heatsinks

    SuperServer 2029P-C1R(T) User's Manual Heatsinks The 2029P-C1R(T) server uses a slightly different heatsink design for each CPU. The SNK- P0068PSC model is used for CPU1, the CPU closer to the mid-chassis fans. Figure 3-3. Heatsink SNK-P0068PSC Figure 3-4. Heatsink SNK-P0068PS (for CPU1) (for CPU2) Note: For CPU1, the SNK-P0068PSC heatsink must be installed with the side with short fins...
  • Page 31: Overview Of The Processor Heatsink Module (Phm)

    Chapter 3: Maintenance and Component Installation Overview of the Processor Heatsink Module (PHM) The Processor Heatsink Module (PHM) contains 1) a heatsink, 2) a narrow processor clip, and 3) the SKX(-F) processor. 1. Heatsink 2. Narrow processor clip 3. SKX(-F) Processor (Bottom View for a non-F Model and CPU2) (Bottom View for an F Model and CPU1)
  • Page 32: Assembling The Processor Package

    SuperServer 2029P-C1R(T) User's Manual Assembling the Processor Package Attach the processor to the narrow processor clip to create the processor package. Caution: Be careful handling the CPU. Do not touch the underside. Wear ESD gloves. 1. On the top corner of the CPU, locate pin 1 (A), marked by a triangle. Also, locate notch B and notch C (and notch D for -F models) on the CPU as shown below.
  • Page 33 Chapter 3: Maintenance and Component Installation CPU (Upside Down) Align Notch D of the CPU w/CPU LGA Lands up and Notch D of the Processor Clip Align Notch C of the CPU Pin 1 and Notch C of the Processor Clip Align Notch B of the CPU and Notch B of the Processor Clip CPU/Heatsink Package...
  • Page 34: Assembling The Processor Heatsink Module (Phm)

    SuperServer 2029P-C1R(T) User's Manual Assembling the Processor Heatsink Module (PHM) After creating the processor package assembly, mount it onto the heatsink to create the processor heatsink module (PHM). 1. Locate "1" on the heatsink label and the corner next to it. With your index finger pressing against the screw at this corner, turn the heatsink upside down with the thermal grease side facing up.
  • Page 35: Preparing The Cpu Socket For Installation

    Chapter 3: Maintenance and Component Installation Non-Fabric CPU and Processor Clip (Upside Down) Triangle on the CPU Triangle on the Processor Clip Heatsink (Upside Down) On Locations of (C, D), the notches snap onto the heat sink’s Assembling the Processor Heatsink Module for SNK-P0068PSC mounting holes (for CPU1) Removing the Dust Cover from the CPU Socket...
  • Page 36: Installing The Processor Heatsink Module (Phm)

    SuperServer 2029P-C1R(T) User's Manual Installing the Processor Heatsink Module (PHM) 1. Locate the triangle (pin 1) on the CPU socket, and locate the triangle (pin 1) at the corner of the PHM that is closest to "1." (If you have difficulty locating pin 1, turn the PHM upside down.
  • Page 37: Connecting An Hfi Carrier Card

    Chapter 3: Maintenance and Component Installation Connecting an HFI Carrier Card A host fabric interface (HFI) carrier card can be connected the JHFI sideband header and to an SKX-F processor. Two HFI headers are located on the X11DPi-N(T) motherboard. JHFI1 is used for CPU 1, and JHFI2 is for CPU2.
  • Page 38: Removing The Processor Heatsink Module From The Motherboard

    SuperServer 2029P-C1R(T) User's Manual Removing the Processor Heatsink Module from the Motherboard Before removing the processor heatsink module (PHM), power down as described in Section 3.1. 1. Using a T30 Torx-bit screwdriver, loosen and remove the screws on the PHM from the socket, starting with the screw marked #4, in the sequence of 4, 3, 2, 1.
  • Page 39: Memory

    DIMMs in one channel and one DIMM in another channel, will result in reduced memory performance. Check the Supermicro website for possible updates to memory support. DIMM Module Population Configuration For optimal memory performance, follow the specifications below when populating memory.
  • Page 40 SuperServer 2029P-C1R(T) User's Manual Key Parameters for DIMM Configurations Parameters Possible Values Number of Channels 1, 2, 3, 4, 5, or 6 Number of DIMMs per Channel 1DPC (1 DIMM Per Channel) or 2DPC (2 DIMMs Per Channel) DIMM Type RDIMM (w/ECC), LRDIMM, 3DS-LRDIMM DIMM Construction - non-3DS RDIMM Raw Cards: A/B (2RX4), C (1RX4), D (1RX8), E (2RX8)
  • Page 41: Install Procedure

    Chapter 3: Maintenance and Component Installation Install Procedure The DIMM slots must be populated in the following order: P1-DIMMA1, P1-DIMMD1, P1- DIMMB1, P1-DIMME1, and P1-DIMMC1, P1-DIMMF1. The blue slots must be populated first. Caution: Exercise caution when installing or removing memory modules to prevent damage to the DIMMs or slots.
  • Page 42: Pcie M.2 Slot

    SuperServer 2029P-C1R(T) User's Manual PCIe M.2 Slot The motherboard has one M.2 slot. M.2 was formerly Next Generation Form Factor (NGFF) and serves to replace mini-PCIe. M.2 allows for a variety of card sizes, increased functionality, and spatial efficiency. The M.2 socket on the motherboard supports PCIe 3.0 X4 (32 Gb/s) SSD cards in the 2280 and 22110 form factors.
  • Page 43: Motherboard Battery

    Chapter 3: Maintenance and Component Installation Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system as described in section 3.1. 1.
  • Page 44: Chassis Components

    The SC213 chassis supports sixteen 2.5" storage drives (HDDs or SSDs) in drive carriers to simplify their removal from the chassis. These carriers also help promote proper airflow. Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website at http://www.
  • Page 45: Installing Drives

    Chapter 3: Maintenance and Component Installation Installing Drives Removing Drive Carriers from the Chassis 1. Press the release button on the drive carrier. This extends the drive carrier handle. 2. Use the handle to pull the carrier out of the chassis (Figure 3-6). 3.
  • Page 46 SuperServer 2029P-C1R(T) User's Manual Figure 3-8. Removing a Dummy Drive from the Drive Carrier Installing a Drive 1. Install a new drive into the carrier with the printed circuit board side facing down so that the mounting holes in the drive align with those in the carrier. 2.
  • Page 47: Dvd Drive Installation (Optional)

    Chapter 3: Maintenance and Component Installation DVD Drive Installation (Optional) The system accomodates an optional slim DVD drive. Side mounting brackets are typically required. Installing a DVD Drive 1. Power down the system as described in Section 3.1 and remove the chassis cover. 2.
  • Page 48: Installing A Device In The 5.25" Drive Bay

    A 5.25" peripheral device, such as a DVD drive • One or two additional fixed SATA or solid state drives For a complete listing of peripheral drive options, visit the Supermicro Web site. Installing a Peripheral Device 1. Power down the system and remove the cover.
  • Page 49 Chapter 3: Maintenance and Component Installation Installing a Storage Drive into a 5.25" Drive Tray One 3.5" drive, or two 2.5" drives with an optional bracket (pn MCP-220-00044-0N) can be installed. Additional cables are also required. 1. Power down the system and remove the cover. 2.
  • Page 50: Installing Expansion Cards

    SuperServer 2029P-C1R(T) User's Manual Installing Expansion Cards The system can accommodate five low-profile PCIe cards. The chassis has seven: the slot nearest the chassis center is not supported by this motherboard, the slot nearest the chassis edge is already filled by a SAS3 controller card. Installing an Expansion Card 1.
  • Page 51: System Fans

    Chapter 3: Maintenance and Component Installation System Fans Three hot-swap fans provide cooling. They can be replaced without powering down the system. Fan speed is controlled by a system temperature setting in IPMI. If a fan fails, the remaining fans will ramp up to full speed. The system can continue to run with a failed fan. Replace any failed fan at your earliest convenience with the same type and model.
  • Page 52: Installing The Air Shrouds

    SuperServer 2029P-C1R(T) User's Manual Installing the Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency. It covers the processors and heatsinks. Installing an Air Shroud The air shroud fits behind the two fans closest to the power supply. Align the pins and press the air shroud into the chassis along the edges.
  • Page 53: Power Supply

    Power Supply The chassis features redundant power supplies. The power modules can be changed without powering down the system. New units can be ordered directly from Supermicro or authorized distributors. These power supplies are auto-switching capable. This feature enables them to automatically sense the input voltage and operate at a 100-120v or 180-240v.
  • Page 54: Chapter 4 Motherboard Connections

    SuperServer 2029P-C1R(T) User's Manual Chapter 4 Motherboard Connections This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A motherboard layout indicating component locations may be found in Chapter 1.
  • Page 55: Headers And Connectors

    SATA is supported on the X11DPi-N(T) motherboard by three iPass connectors and two SATA powered ports. The powered ports, S-SATA4/S-SATA5, are yellow connectors with power pins built in. They can be used with Supermicro SuperDOMs and do not require external power cables.
  • Page 56 SuperServer 2029P-C1R(T) User's Manual TPM Header The JTPM1 header is used to connect a Trusted Platform Module (TPM)/Port 80, which is available from a third-party vendor. A TPM/Port 80 connector is a security device that supports encryption and authentication in hard drives. It allows the motherboard to deny access if the TPM associated with the hard drive is not installed in the system.
  • Page 57 Chapter 4: Motherboard Connections Power SMBus (I C) Header The Power System Management Bus (I C) connector (JPI C1) monitors the power supply, fan, and system temperatures. Power SMBus Header Pin Definitions Pin# Definition Clock Data PMBUS_Alert Ground +3.3V 4-pin BMC External I C Header A System Management Bus header for IPMI 2.0 is located at JIPMB1.
  • Page 58 C) headers (JNVI2C1/2) are used for PCIe SMBus clock and data connections and provide hot-plug support by a dedicated SMBus interface. This feature is only available for a Supermicro complete system with a proprietary NVMe add-on card and cable installed. NVMe SMBus Header...
  • Page 59: Control Panel

    Chapter 4: Motherboard Connections Control Panel JF1 contains header pins for various control panel connections. See the figure below for the pin locations and definitions of the control panel buttons and LED indicators. All JF1 wires have been bundled into a single cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the motherboard.
  • Page 60 SuperServer 2029P-C1R(T) User's Manual Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Power Fail LED Pin Definitions (JF1) Pin# Definition 3.3V PWR Supply Fail Overheat (OH)/Fan Fail Connect an LED cable to pins 7 and 8 of JF1 to use the Overheat/Fan Fail LED connections. The LED on pin 8 provides warnings of overheat or fan failure.
  • Page 61: Data Cables

    Chapter 4: Motherboard Connections HDD LED/UID Switch The HDD LED/UID Switch connection is located on pins 13 and 14 of JF1. Attach a cable to Pin 14 to show hard drive activity status. Attach a cable to Pin 13 to use UID switch. Refer to the table below for pin definitions.
  • Page 62: Input/Output Ports And Interface Buttons

    SuperServer 2029P-C1R(T) User's Manual 4.3 Input/Output Ports and Interface Buttons The rear I/O panel offers these ports and control switches. Figure 4-2. Back Panel I/O Ports Back Panel I/O Ports Description No. Description COM1 USB 1 USB 4 GLAN1 (2029P-C1R), 10G_LAN1 (2029P-C1RT) USB 5 GLAN2 (2029P-C1R), 10G_LAN2 (2029P-C1RT) IPMI LAN...
  • Page 63: Jumpers

    Chapter 4: Motherboard Connections 4.4 Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
  • Page 64 SuperServer 2029P-C1R(T) User's Manual Management Engine (ME) Recovery Use jumper JPME1 to select ME Firmware Recovery mode, which will limit resource allocation for essential system operation only in order to maintain normal power operation and management. In the single operation mode, online upgrade will be available via Recovery mode.
  • Page 65: Led Indicators

    Chapter 4: Motherboard Connections I2C Bus for VRM Jumpers JVRM1 and JVRM2 allow the BMC or the PCH to access CPU and memory VRM controllers. Jumper Settings Jumper Setting Definition BMC (Normal) 4.5 LED Indicators LAN LEDs The LAN ports are located on the I/O back panel on the motherboard. Each Ethernet LAN port has two LEDs.
  • Page 66 SuperServer 2029P-C1R(T) User's Manual BMC Heartbeat LED LEDM1 is the BMC heartbeat indicator. When the LED is blinking green, BMC is functioning normally. BMC Heartbeat LED Indicator LED Color Definition Green: BMC Normal Blinking Onboard Power LED The Onboard Power LED is located at LE2 on the motherboard. When this LED is on, the system is on.
  • Page 67: Chapter 5 Software

    You must first configure RAID settings (if using RAID) before you install the Windows OS and the software drivers. To configure RAID settings, please refer to the RAID Configuration User Guides posted on our website at www.supermicro.com/support/manuals. Installing the Windows OS for a RAID System 1.
  • Page 68: Driver Installation

    SuperServer 2029P-C1R(T) User's Manual 5.2 Driver Installation The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp.supermicro. com. Some of these must be installed, such as the chipset driver. After accessing the FTP site, go into the CDR_Images directory and locate the ISO file for your motherboard.
  • Page 69: Superdoctor ® 5

    5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 70: Ipmi

    The X11DPi-N(T) supports the Inteliigent Platform Management Interface (IPMI). IPMI is used to provide remote access, monitoring and management. There are several BIOS settings that are related to IPMI. For general documentation and information on IPMI, please visit our website at: http://www.supermicro.com/products/nfo/IPMI.cfm.
  • Page 71: Chapter 6 Bios

    Chapter 6: BIOS Chapter 6 BIOS 6.1 Introduction This chapter describes the AMI BIOS setup utility for the X11DPi-N(T) and provides the instructions on navigating the setup screens. The BIOS is stored in a Flash EEPROM and can be updated. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted since this manual was published.
  • Page 72 HH:MM:SS format. Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00. The date's default value is 01/01/2016 after RTC reset. Supermicro X11DPi-N/X11DPi-NT (Motherboard model) BIOS Version Build Date (of the BIOS)
  • Page 73: Advanced Setup Configurations

    Chapter 6: BIOS 6.3 Advanced Setup Configurations Use the arrow keys to select the Advanced tab and press <Enter> to access the submenu items. Caution: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRAM timing setting may make the system unstable. If this occurs, revert to the manufacture default settings.
  • Page 74 SuperStorage Server 2029P-C1R(T) User's Manual Option ROM Messages Use this feature to set the display mode for the Option ROM. Select Keep Current to use the current AddOn ROM display setting. Select Force BIOS to use the Option ROM display mode set by the system BIOS.
  • Page 75 Chapter 6: BIOS CPU Configuration  Warning: Setting the wrong values in the following sections may cause the system to malfunc- tion. Processor Configuration  The following CPU information will be displayed: • Processor BSP Revision • Processor Socket • Processor ID •...
  • Page 76 SuperStorage Server 2029P-C1R(T) User's Manual PPIN Control Select Unlock/Enable to use the Protected-Processor Inventory Number (PPIN) in the system. The options are Unlock/Enable and Unlock/Disable. Hardware Prefetcher (Available when supported by the CPU) If this feature is set to Enable, the hardware prefetcher will prefetch streams of data and instructions from the main memory to the Level 2 (L2) cache to improve CPU performance.
  • Page 77 Chapter 6: BIOS Advanced Power Management Configuration  CPU P State Control  SpeedStep (PStates) EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency in an effort to reduce power consumption and heat dissipation.
  • Page 78 SuperStorage Server 2029P-C1R(T) User's Manual Enhanced Halt State (C1E) Select Enable to enable "Enhanced Halt State" support, which will significantly reduce the CPU's power consumption by minimizing CPU's clock cycles and reduce voltage during a "Halt State." The options are Disable and Enable. Package C State Control ...
  • Page 79 Chapter 6: BIOS Link L0p Enable Select Enable to enable Link L0p. The options are Disable, Enable, and Auto. Link L1 Enable Select Enable to enable Link L1 (Level 1 link). The options are Disable, Enable, and Auto. IO Directory Cache Select Enable for the IODC (I/O Directory Cache) to generate snoops instead of generating memory lockups for remote IIO (InvIToM) and/or WCiLF (Cores).
  • Page 80 SuperStorage Server 2029P-C1R(T) User's Manual Memory Topology  This item displays the information of onboard memory modules as detected by the BIOS. • P1 DIMMA1 • P1 DIMMB1 • P2 DIMMA1 • P2 DIMMB1 Memory RAS (Reliability_Availability_Serviceability) Configuration  Use this submenu to configure the following Memory RAS settings. Static Virtual Lockstep Mode Select Enable to support Static Virtual Lockstep mode to enhance memory performance.
  • Page 81 Chapter 6: BIOS roughly 64 GB of memory behind the IO hub will be scrubbed every day. The options are Enable and Disable. Patrol Scrub Interval Use this item to specify the number of hours (between 0 to 24) required for the system to complete a full patrol scrubbing.
  • Page 82 SuperStorage Server 2029P-C1R(T) User's Manual • PCI-E Port Link Max • PCI-E Port Link Speed PCI-E Port Max (Maximum) Payload Size (Available for CPU 1 Configuration only) Select Auto for the system BIOS to automatically set the maximum payload value for a PCI-E device specified by to user to enhance system performance.
  • Page 83 Chapter 6: BIOS PassThrough DMA Select Enable for the Non-Iscoh VT-d engine to pass through DMA (Direct Memory Access) to enhance system performance. The options are Enable and Disable. Select Enable to enable ATS (Address Translation Services) support for the Non-Iscoh VT-d engine to enhance system performance.
  • Page 84 SuperStorage Server 2029P-C1R(T) User's Manual South Bridge The following South Bridge information will display: • USB Module Version • USB Devices Legacy USB Support Select Enabled to support onboard legacy USB devices. Select Auto to disable legacy support if there are no legacy USB devices present. Select Disable to have all USB devices available for EFI applications only.
  • Page 85 Chapter 6: BIOS SATA Configuration  When this submenu is selected, the AMI BIOS automatically detects the presence of the SATA devices that are supported by the Intel PCH chip and displays the following items: SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH chip. The options are Enable and Disable.
  • Page 86 SuperStorage Server 2029P-C1R(T) User's Manual SATA Device Type Use this item to specify if the device installed on the SATA port selected by the user should be connected to a Solid State drive or a Hard Disk Drive. The options are Hard Disk Drive and Solid State Drive.
  • Page 87 Chapter 6: BIOS Spin Up Device On an edge detect from 0 to 1, set this item to allow the sSATA device installed on the sSATA port specified by the user to start a COMRESET initialization. The options are Enable and Disable. sSATA Device Type Use this item to specify if the device installed on the sSATA port specified by the user should be connected to a Solid State drive or a Hard Disk Drive.
  • Page 88 SuperStorage Server 2029P-C1R(T) User's Manual MMCFG Base This feature determines the lowest MMCFG (Memory-Mapped Configuration) base assigned to PCI devices. The options are 1G, 1.5G, 1.75G. 2G, 2.25G, and 3G. VGA Priority Use this item to select the graphics device to be used as the primary video display for system boot.
  • Page 89 Chapter 6: BIOS Ipv4 PXE Support Select Enabled to enable Ipv4 PXE boot support. If this feature is disabled, it will not create the Ipv4 PXE boot option. The options are Disabled and Enabled. Ipv4 HTTP Support Select Enabled to enable Ipv4 HTTP boot support. If this feature is disabled, it will not create the Ipv4 HTTP boot option.
  • Page 90 SuperStorage Server 2029P-C1R(T) User's Manual The options for Serial Port 1 are Auto, (IO=3F8h; IRQ=4), (IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12); (IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), and (IO=2E8h;...
  • Page 91 Chapter 6: BIOS Bits Per second Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).
  • Page 92 SuperStorage Server 2029P-C1R(T) User's Manual Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SCO, ESCN, and VT400. Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection after BIOS POST.
  • Page 93 Chapter 6: BIOS Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits.
  • Page 94 SuperStorage Server 2029P-C1R(T) User's Manual Legacy Console Redirection Settings  Legacy Console Redirection Settings Use the feature to select the COM port to display redirection of Legacy OS and Legacy OPROM messages. The default setting is COM1. Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS) The submenu allows the user to configure Console Redirection settings to support Out-of- Band Serial Port management.
  • Page 95 Chapter 6: BIOS ACPI Settings  Use this feature to configure Advanced Configuration and Power Interface (ACPI) power management settings for your system. NUMA Support (Available when the OS supports this feature) Select Enabled to enable Non-Uniform Memory Access support to enhance system perfor- mance.
  • Page 96 SuperStorage Server 2029P-C1R(T) User's Manual • Active PCR Banks • Available PCR Banks Pending Operation Use this feature to schedule a TPM-related operation to be performed by a security (TPM) device at the next system boot to enhance system data integrity. Your system will reboot to carry out a pending TPM operation.
  • Page 97 "IIO Configuration" in the "Chipset/North Bridge" submenu). Note 2: For more information on TPM, please refer to the TPM manual at http://www. supermicro.com/manuals/other. Intel Virtual RAID on CPU When this submenu is selected and the RAID devices are detected, the BIOS screen displays the following items: Intel VROC with VMD Technology 5.0.0.1205...
  • Page 98: Event Logs

    SuperStorage Server 2029P-C1R(T) User's Manual 6.4 Event Logs Use this tab page to configure Event Log settings. Change SMBIOS Event Log Settings Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system boot. The options are Enabled and Disabled. Erasing Settings Erase Event Log Select Enabled to erase all error events in the SMBIOS (System Management BIOS) log...
  • Page 99 Chapter 6: BIOS SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events. The options are Enabled and Disabled. MECI (Multiple Event Count Increment) Enter the increment value for the multiple event counter. Enter a number between 1 to 255. The default setting is 1.
  • Page 100: Ipmi

    SuperStorage Server 2029P-C1R(T) User's Manual 6.5 IPMI Use this tab page to configure Intelligent Platform Management Interface (IPMI) settings. The following items will be displayed: • IPMI Firmware Revision • Status of BMC System Event Log Enabling/Disabling Options SEL Components Select Enabled for all system event logging at bootup.
  • Page 101 Chapter 6: BIOS When SEL is Full This feature allows the user to determine what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full.
  • Page 102: Security

    SuperStorage Server 2029P-C1R(T) User's Manual IPMI LAN Selection Use this feature to select the type of the IPMI LAN. The options are Dedicated, Shared, and Failover. VLAN Select Enabled to enable IPMI VLAN function support. The options are Enabled and Disabled.
  • Page 103 Chapter 6: BIOS User Password Use this feature to set the user password which is required to enter the BIOS setup utility. The length of the password should be from 3 characters to 20 characters long. Password Check Select Setup for the system to check for a password at Setup. Select Always for the system to check for a password at bootup or upon entering the BIOS Setup utility.
  • Page 104 SuperStorage Server 2029P-C1R(T) User's Manual Save All Secure Boot Variables  This feature allows the user to set and save the secure boot key variables specified by the user. Secure Boot Variables Secure Boot Variable/Size/Key#/Key Sources Platform Key (PK)  This feature allows the user to enter and configure a set of values to be used as a platform firmware key for the system.
  • Page 105: Boot

    Chapter 6: BIOS 6.7 Boot Use this tab page to configure Boot Settings. Boot Mode Select Use this feature to select the type of devices that the system is going to boot from. The options are Legacy, UEFI (Unified Extensible Firmware Interface), and Dual. Fixed Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boot.
  • Page 106 SuperStorage Server 2029P-C1R(T) User's Manual Add New Boot Option This feature allows the user to add a new boot option to the boot priority features for your system. Add Boot Option Use this item to specify the name for the new boot option. Path for Boot Option Use this feature to enter the path for the new boot option in the format fsx:\path\filename.efi.
  • Page 107 Chapter 6: BIOS Delete Drive Option Select the target boot driver to delete from the boot priority list.  Hard Disk Drive BBS Priorities • Boot Option #1 - #5  Network Drive BBS Priorities • Boot Option #1  USB Key Drive BBS Priorities •...
  • Page 108: Save & Exit

    SuperStorage Server 2029P-C1R(T) User's Manual 6.8 Save & Exit Use this tab page to configure Save & Exit settings. Save Options Discard Changes and Exit Select this option to quit the BIOS setup without making any permanent changes to the system configuration and reboot the computer.
  • Page 109 Chapter 6: BIOS Default Options Restore Optimized Defaults To set this feature, select Restore Defaults from the Exit menu and press <Enter> to load manufacturer default settings which are intended for maximum system performance but not for maximum stability. Save As User Defaults To set this feature, select Save as User Defaults from the Exit menu and press <Enter>.
  • Page 110: Appendix A Bios Error Codes

    SuperServer 2029P-C1R(T) User's Manual Appendix A BIOS Error Codes A-1 BIOS Error Beep (POST) Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
  • Page 111 When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20). For information on AMI updates, please refer to http://www.ami.com/products/.
  • Page 112: Appendix B Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 113 Appendix B: Standardized Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 114 SuperServer 2029P-C1R(T) User's Manual . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 115 Appendix B: Standardized Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 116 SuperServer 2029P-C1R(T) User's Manual Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 117 Appendix B: Standardized Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告...
  • Page 118 SuperServer 2029P-C1R(T) User's Manual ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت قبم‬ ‫انىصىل إىن امنناطق انداخهيت نههيكم نتثبيج أو إ ز انت مكىناث الجهاز‬ 경고! 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터...
  • Page 119 Appendix B: Standardized Warning Statements Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 120 SuperServer 2029P-C1R(T) User's Manual Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 121 Appendix B: Standardized Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 122 SuperServer 2029P-C1R(T) User's Manual ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일하거나 제 조사에서...
  • Page 123 Appendix B: Standardized Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 124 SuperServer 2029P-C1R(T) User's Manual Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 125 Appendix B: Standardized Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 126 SuperServer 2029P-C1R(T) User's Manual ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
  • Page 127 Appendix B: Standardized Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 128 SuperServer 2029P-C1R(T) User's Manual Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 129 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 130 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 131 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 132: Appendix C System Specifications

    Eight SATA 3.0 ports supported by Intel PCH (I-SATA 0-3, I-SATA 4-7) Four S-SATA 3.0 ports supported by Intel SCU Two SATA 3.0 ports with power-pins built-in, with support for Supermicro SuperDOM (S-SATA4/S-ISATA5) Chassis SC213AC-R1K23LPB; 2U Rackmount, 17.2 x 3.5 x 28.8 in. / 438 x 88 x 760 mm. (W x H x D) Weight Gross weight: 63 lbs.
  • Page 133 Appendix C: System Specifications Operating Environment Operating Temperature: 10º to 35º C (50º to 95º F) Non-operating Temperature: -40º to 60º C (-40º to 140º F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55032 Class A, EN 61000-3-2/3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,...
  • Page 134: Appendix D Uefi Bios Recovery

    Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
  • Page 135 USB device or a writable CD/DVD. Notes: 1. If you cannot locate the "Super.ROM" file in your drive disk, visit our website www.supermicro.com to download the BIOS package. Extract the BIOS binary im- age into a USB flash device and rename it "Super.ROM" for the BIOS recovery use. 2.
  • Page 136 SuperServer 2029P-C1R(T) User Manual 3. After locating the healthy BIOS binary image, the system will enter the BIOS Recovery menu as shown below. Note: At this point, you may decide if you want to start the BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below.
  • Page 137 Appendix D: UEFI BIOS Recovery 5. After the BIOS recovery process is complete, press any key to reboot the system. 6. Using a different system, extract the BIOS package into a USB flash drive. 7. Press <Del> continuously during system boot to enter the BIOS Setup utility. From the top of the tool bar, select Boot to enter the submenu.
  • Page 138 SuperServer 2029P-C1R(T) User Manual 8. When the UEFI Shell prompt appears, type fs# to change the device directory path. Go to the directory that contains the BIOS package you extracted earlier from Step 6. Enter flash.nsh BIOSname.### at the prompt to start the BIOS update process. Note: Do not interrupt this process until the BIOS flashing is complete.

This manual is also suitable for:

Superserver 2029p-c1r